We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup
Jackery SolarSaga 100 Prime
Jackery

SolarSaga 100 Prime

100 W panel with an MC4 plug. Expect about 70 W at midday in clear sun.

Where to buyPrices checked Oct 28, 2026
Jackery store
$50 off the store's usual $249
$199Buy

We may earn a commission if you buy through these links. It never changes a verdict.

The four numbers on the label

Every panel has a sticker on the back with these. The station cares about the first two most.

VocManual
22.7 V
Open-circuit voltage

The highest voltage the panel makes, with nothing plugged in. This must stay under the station's limit, including on cold mornings.

IscManual
5.5 A
Short-circuit current

The most current it can push. Stations cap current; over the cap you lose watts, or on some brands it is not allowed.

VmpManual
18.7 V
Voltage at max power

The working voltage while charging. Must be above the station's minimum or charging will not start.

ImpManual
5.3 A
Current at max power

The working current while charging. Vmp times Imp is roughly the rated watts.

Open-circuit voltage by morning temperatureone panel, -0.30%/°C, typical value, not published for this panel
26.0 V-10F
25.2 V10F
24.4 V32F
23.7 V50F
22.7 V77F

Why it matters: a station's input limit is a hard number. Two of these panels in series on a 10F morning make 50.5 V. That is fine for a 60 V input and not for a 27 V one.

Which stations it works with

One panel, 20F morning. 100 take it cleanly. Tap a row for the wiring and cables.

EcoFlow RIVER 3 PlusAbout 99 W into the XT60i. Use an MC4 to XT60i solar cable.
Works
EcoFlow DELTA 3 PlusAbout 99 W into the XT60i. Use an MC4 to XT60i solar cable.
Works
EcoFlow DELTA Pro 3About 99 W into the XT60i (Low-PV). Use an MC4 to XT60i solar cable.
Works
Jackery Explorer 1000 v2About 99 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
Jackery Explorer 2000 PlusAbout 99 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
BLUETTI AC70About 99 W into the XT60 (XT60PM-M). Use an MC4 to XT60 solar cable.
Works
BLUETTI AC180About 99 W into the DC7909. Use an MC4 to DC7909 solar cable; check whether one came in the box.
Works
BLUETTI AC200LAbout 99 W into the DC input (via DC input cable + solar charging cable). Use the solar charging cable that came with the station (MC4 on the panel side).
Works
Show all 113 stationsShow fewer
Anker SOLIX C1000 Gen 2The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
EcoFlow RIVER 2About 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow RIVER 2 MaxAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow RIVER 2 Max 500About 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow RIVER 2 ProAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow TRAIL 300 DCAbout 99 W into the Solar/Car input (XT60). Use an MC4 to XT60 solar cable.
Works
EcoFlow DELTA 3 ClassicAbout 99 W into the Solar/Car input (XT60i). Use an MC4 to XT60i solar cable.
Works
EcoFlow DELTA 3About 99 W into the Solar/Car input (XT60i). Use an MC4 to XT60i solar cable.
Works
EcoFlow DELTA 3 MaxAbout 99 W into the Solar/Car input (XT60i). Use an MC4 to XT60i solar cable.
Works
EcoFlow DELTA 3 Max PlusAbout 99 W into the Solar/Car input 1 (XT60i). Use an MC4 to XT60i solar cable.
Works
EcoFlow DELTA 3 UltraAbout 99 W into the Solar input (XT60i). Use an MC4 to XT60i solar cable.
Works
EcoFlow DELTA 3 Ultra PlusAbout 99 W into the Solar input 1 (XT60i). Use an MC4 to XT60i solar cable.
Works
EcoFlow DELTA 2 MaxAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow DELTA ProAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow DELTA miniAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow DELTA 1300 (1260Wh)About 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow DELTA 1000About 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow RIVER MaxAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow RIVER Max PlusAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow RIVER miniAbout 99 W into the DC input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow RIVER PlusAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow RIVERAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI EB3AAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC2AAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Pioneer 50 (AC60)About 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Pioneer MD (AC180T)About 99 W into the Solar input (XT60). Use an MC4 to XT60 solar cable.
Works
BLUETTI Pioneer 150 (AC240)About 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Apex 300About 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC180PAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC200MAXAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC200P LAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC50BAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC50PAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC70PAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI EB70SAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI EP500ProAbout 99 W into the PV input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 10 MiniAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 30 V2About 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 100 V2About 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 100 miniAbout 99 W into the DC input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 200 V2About 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 300About 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 400About 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Handsfree 1About 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI PS72The manual or page does not give a current limit for this input, so current was not checked.
Works
BLUETTI Pioneer NaAbout 99 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Premium 100 V2About 99 W into the DC input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Premium 200 V2About 99 W into the PV input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
Anker SOLIX C200 DCThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX C200XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX C300The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX C300 DCThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX C300XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX C1000X Gen 2About 99 W into the XT60i. Use an MC4 to XT60i solar cable.
Works
Anker SOLIX C1000XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX C2000 Gen 2The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX F1500The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX F2600The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX F3000The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX F3800 PlusThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX S2000The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery Explorer 300 v2About 99 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
Jackery Explorer 300DAbout 99 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
Jackery Explorer 600 v2The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery Explorer 1000The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery Explorer 1000 PlusAbout 99 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
Jackery Explorer 1500 v2About 99 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
Jackery Explorer 1500 UltraAbout 99 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
Jackery Explorer 2000 v2The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery Explorer 5000 PlusAbout 99 W into the Low-PV (DC8020). Needs an MC4 to DC8020 adapter cable.
Works
Jackery HomePower 1000 v2The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery HomePower 1000 Plus v2The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery HomePower 2000 Plus v2The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery HomePower 3000About 99 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
Jackery HomePower 3600 PlusAbout 99 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
Jackery HomePower 3600 Pro MaxAbout 99 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
Goal Zero Yeti 300The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 500The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 700The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 1500The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti PRO 4000The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 1000XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 1500XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 3000XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 6000XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
DJI Power 500About 99 W into the XT60, Solar Panel Adapter Module channel 1. Use an MC4 to XT60 solar cable.
Works
DJI Power 1000About 99 W into the XT60, Solar Panel Adapter Module channel 1. Use an MC4 to XT60 solar cable.
Works
DJI Power 2000About 99 W into the XT60, Solar Panel Adapter Module channel 1. Use an MC4 to XT60 solar cable.
Works
DJI Power 1000 MiniThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery Explorer 300 PlusThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery Explorer 100 PlusThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery Explorer 240 v2The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
EcoFlow DELTA Pro UltraOpen-circuit voltage 22.7V is below the 80V minimum for this input, so it will not start charging.
Don't connect
EcoFlow DELTA Pro Ultra XOpen-circuit voltage 22.7V is below the 80V minimum for this input, so it will not start charging.
Don't connect
BLUETTI AC200POpen-circuit voltage 22.7V is below the 35V minimum for this input, so it will not start charging.
Don't connect
BLUETTI EP500Open-circuit voltage 22.7V is below the 55V minimum for this input, so it will not start charging.
Don't connect
Goal Zero Yeti 500XOpen-circuit voltage 22.7V is above the station's 22V limit. Going over a station's input voltage limit can damage it.
Don't connect
Goal Zero Yeti 200XOpen-circuit voltage 22.7V is above the station's 22V limit. Going over a station's input voltage limit can damage it.
Don't connect
EcoFlow TRAIL 200 DCNot enough confirmed numbers to check yet.
EcoFlow TRAIL Plus 300 DCNot enough confirmed numbers to check yet.
EcoFlow RIVER ProNot enough confirmed numbers to check yet.
BLUETTI Handsfree 2Not enough confirmed numbers to check yet.
Anker SOLIX C200X DCNot enough confirmed numbers to check yet.
Anker SOLIX S5000Not enough confirmed numbers to check yet.
Jackery Explorer 300Not enough confirmed numbers to check yet.

Quick answers

Which power stations work with the Jackery SolarSaga 100 Prime?

Of the 106 power stations we can check, 100 take one Jackery SolarSaga 100 Prime cleanly, even on a 20°F morning (for example the EcoFlow RIVER 3 Plus, EcoFlow DELTA 3 Plus, EcoFlow DELTA Pro 3).

What is the open-circuit voltage of the Jackery SolarSaga 100 Prime?

22.7 V on the label (standard test conditions). It rises in the cold: about 24.9 V at 20°F and 25.6 V at 0°F, so check it against your station's limit on your coldest morning.

Can I wire two Jackery SolarSaga 100 Prime panels in series?

In series the voltages add: two make about 45.4 V open-circuit (49.7 V at 20°F). In parallel the currents add: about 11.1 A. Your station must accept whichever you choose.

Sources

From the manualLabel values from the Jackery SolarSaga 100 Prime user manual. Price from the brand store on Oct 28, 2026.jackery.com