We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the Jackery SolarSaga 100 Prime work with the Goal Zero Yeti 300?

Yes. One Jackery SolarSaga 100 Prime works with the Goal Zero Yeti 300: about 24.9 V on a 20°F morning against the station's 28 V limit, and about 99 W in full sun. Two panels: works (2 panels in parallel on 8mm), about 187 W.

Verdict

Works

1 x SolarSaga 100 Prime into the Yeti 300 (1 panel on 8mm) stays inside 12.3 to 28 V and under 10 A, even at 20F.

1 x SolarSaga 100 Prime1 panel on 8mm
Yeti 3008mm
Expected
99W
Voltage at 20F
24.9V
limit 28 V
Current
5.3A
cap 10 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • Goal Zero says a 200 W panel needs its HPP to 8mm connector for this station.
  • Model JS-100E in the manual. Bifacial: 108 W with light on the back (BNPI).
Cables to buy
  • Needs an MC4 to 8mm adapter cable.
Jackery SolarSaga 100 Prime

100 W, open-circuit 22.7 V, short-circuit 5.5 A, working 18.7 V / 5.3 A. Manual Panel details

Goal Zero Yeti 300

Solar input 8mm: 12.3 to 28 V, 200 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on 8mm
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
8mm24.910.6187Works
2 panels in series on 8mm
Open-circuit voltage 45.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
8mm49.75.30Don't connect

Quick answers

Will the Jackery SolarSaga 100 Prime work with the Goal Zero Yeti 300?

Yes. One Jackery SolarSaga 100 Prime works with the Goal Zero Yeti 300: about 24.9 V on a 20°F morning against the station's 28 V limit, and about 99 W in full sun. Two panels: works (2 panels in parallel on 8mm), about 187 W.

Can I connect two SolarSaga 100 Prime panels to the Yeti 300?

Yes, 2 panels in parallel on 8mm. That gives about 187 W.

What cable do I need to connect the SolarSaga 100 Prime to the Yeti 300?

Needs an MC4 to 8mm adapter cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One SolarSaga 100 Prime goes from 22.7 V on its label to about 24.9 V at 20°F and 25.6 V at 0°F. The Yeti 300 accepts up to 28 V on the 8mm.

Where to buy

$199 at the Jackery store, Oct 28, 2026
Buy
Out of stock at the Goal Zero store
View at store

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the Yeti 300

→Jackery SolarSaga 200 (JS-200D), about 200 W with two
→BLUETTI PV200D, about 200 W with two
→EcoFlow 175W Rigid Solar Panel, about 200 W with two
→BLUETTI SP100L Solar Panel, about 200 W with two
→BLUETTI SP200L Solar Panel, about 200 W with two

All 33 panels checked against the Yeti 300

Rules we applied
  • Goal Zero Yeti 300: solar input 12.3 to 28 V on the Solar in (8mm). Goal Zero does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 22.7 V becomes 24.9 V.
  • Current over the 10 A cap is safe: the station takes 10 A and you get fewer watts. We count only the capped watts.
  • Max 200 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
From the brand's pageYeti 300 spec page, solar input
Checked Oct 28, 2026