We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the Jackery SolarSaga 100 Prime work with the Anker SOLIX C300?

Yes. One Jackery SolarSaga 100 Prime works with the Anker SOLIX C300: about 24.9 V on a 20°F morning against the station's 28 V limit, and about 99 W in full sun. Two panels: works (2 panels in parallel on XT60), about 100 W.

Verdict

Works

1 x SolarSaga 100 Prime into the C300 (1 panel on XT60) stays inside 11 to 28 V and under 8.2 A, even at 20F.

1 x SolarSaga 100 Prime1 panel on XT60
C300XT60
Expected
99W
Voltage at 20F
24.9V
limit 28 V
Current
5.3A
cap 8.2 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • Anker's manual: the panel voltage must be 11 to 28V or the station can be damaged. Anker does not say if that is open-circuit voltage, so the checker uses the stricter reading.
  • Model JS-100E in the manual. Bifacial: 108 W with light on the back (BNPI).
Cables to buy
  • Use an MC4 to XT60 solar cable.
Jackery SolarSaga 100 Prime

100 W, open-circuit 22.7 V, short-circuit 5.5 A, working 18.7 V / 5.3 A. Manual Panel details

Anker SOLIX C300

Solar input XT60: 11 to 28 V, 100 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on XT60
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
XT6024.910.6100Works
2 panels in series on XT60
Open-circuit voltage 45.4V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
XT6049.75.30Don't connect

Quick answers

Will the Jackery SolarSaga 100 Prime work with the Anker SOLIX C300?

Yes. One Jackery SolarSaga 100 Prime works with the Anker SOLIX C300: about 24.9 V on a 20°F morning against the station's 28 V limit, and about 99 W in full sun. Two panels: works (2 panels in parallel on XT60), about 100 W.

Can I connect two SolarSaga 100 Prime panels to the C300?

Yes, 2 panels in parallel on XT60. That gives about 100 W.

What cable do I need to connect the SolarSaga 100 Prime to the C300?

Use an MC4 to XT60 solar cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One SolarSaga 100 Prime goes from 22.7 V on its label to about 24.9 V at 20°F and 25.6 V at 0°F. The C300 accepts up to 28 V on the XT60.

Where to buy

$199 at the Jackery store, Oct 28, 2026
Buy
Out of stock at the Anker SOLIX store
View at storeAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the C300

→Jackery SolarSaga 200 (JS-200E), about 100 W with two
→Jackery SolarSaga 200 (JS-200D), about 100 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 100 W with two
→BLUETTI PV200D, about 100 W with two
→EcoFlow 100W Rigid Solar Panel, about 100 W with two

All 33 panels checked against the C300

Rules we applied
  • Anker SOLIX C300: solar input 11 to 28 V on the Solar in (XT60). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 22.7 V becomes 24.9 V.
  • Current over the 8.2 A cap is safe: the station takes 8.2 A and you get fewer watts. We count only the capped watts.
  • Max 100 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
Checked Oct 28, 2026