Will the EcoFlow 100W Rigid Solar Panel work with the Anker SOLIX C300?
Yes. One EcoFlow 100W Rigid Solar Panel works with the Anker SOLIX C300: about 22.4 V on a 20°F morning against the station's 28 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60), about 100 W.
Works
1 x 100W Rigid Solar Panel into the C300 (1 panel on XT60) stays inside 11 to 28 V and under 8.2 A, even at 20F.
- The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
- Anker's manual: the panel voltage must be 11 to 28V or the station can be damaged. Anker does not say if that is open-circuit voltage, so the checker uses the stricter reading.
- Use an MC4 to XT60 solar cable.
100 W, open-circuit 20.3 V, short-circuit 6.3 A, working 17.1 V / 5.9 A. Brand page Panel details
Anker SOLIX C300Solar input XT60: 11 to 28 V, 100 W max. Manual Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in parallel on XT60 The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | XT60 | 22.4 | 11.8 | 100 | Works |
| 2 panels in series on XT60 Open-circuit voltage 40.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it. | XT60 | 44.8 | 5.9 | 0 | Don't connect |
Quick answers
Will the EcoFlow 100W Rigid Solar Panel work with the Anker SOLIX C300?
Yes. One EcoFlow 100W Rigid Solar Panel works with the Anker SOLIX C300: about 22.4 V on a 20°F morning against the station's 28 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60), about 100 W.
Can I connect two 100W Rigid Solar Panel panels to the C300?
Yes, 2 panels in parallel on XT60. That gives about 100 W.
What cable do I need to connect the 100W Rigid Solar Panel to the C300?
Use an MC4 to XT60 solar cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One 100W Rigid Solar Panel goes from 20.3 V on its label to about 22.4 V at 20°F and 23.2 V at 0°F. The C300 accepts up to 28 V on the XT60.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the C300
- Anker SOLIX C300: solar input 11 to 28 V on the Solar in (XT60). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
- Cold raises panel voltage: we add 0.33% per °C below 77F (25°C), this panel's own figure. At 20F one panel's 20.3 V becomes 22.4 V.
- Current over the 8.2 A cap is safe: the station takes 8.2 A and you get fewer watts. We count only the capped watts.
- Max 100 W on this input.
- Cold-morning voltage uses this panel's own coefficient from its manual, 0.33% per °C.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.