We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the Anker SOLIX PS100 Bifacial work with the Goal Zero Yeti PRO 4000?

Yes. One Anker SOLIX PS100 Bifacial works with the Goal Zero Yeti PRO 4000: about 28.4 V on a 20°F morning against the station's 150 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on HPP), about 200 W.

Verdict

Works

1 x PS100 Bifacial into the Yeti PRO 4000 (1 panel on HPP) stays inside 13.3 to 150 V and under 30 A, even at 20F.

1 x PS100 Bifacial1 panel on HPP
Yeti PRO 4000HPP
Expected
100W
Voltage at 20F
28.4V
limit 150 V
Current
4.6A
cap 30 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Cables to buy
  • Needs an MC4 to HPP (Anderson Powerpole) adapter cable.
Anker SOLIX PS100 Bifacial

100 W, open-circuit 25.9 V, short-circuit 4.9 A, working 21.6 V / 4.6 A. Unconfirmed Panel details

Goal Zero Yeti PRO 4000

Solar input HPP: 13.3 to 150 V; 8mm: 12.3 to 28 V, 3000 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on HPP
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
HPP28.49.3200Works
2 panels in series on HPP
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
HPP56.74.6200Works
1 panel on HPP + 1 panel on 8mm
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
HPP + 8mm28.44.6200Works, with a catch
2 panels in parallel on 8mm
Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage.
8mm28.49.3200Works, with a catch
2 panels in series on 8mm
Open-circuit voltage 51.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
8mm56.74.60Don't connect

Quick answers

Will the Anker SOLIX PS100 Bifacial work with the Goal Zero Yeti PRO 4000?

Yes. One Anker SOLIX PS100 Bifacial works with the Goal Zero Yeti PRO 4000: about 28.4 V on a 20°F morning against the station's 150 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on HPP), about 200 W.

Can I connect two PS100 Bifacial panels to the Yeti PRO 4000?

Yes, 2 panels in parallel on HPP. That gives about 200 W.

What cable do I need to connect the PS100 Bifacial to the Yeti PRO 4000?

Needs an MC4 to HPP (Anderson Powerpole) adapter cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PS100 Bifacial goes from 25.9 V on its label to about 28.4 V at 20°F and 29.2 V at 0°F. The Yeti PRO 4000 accepts up to 150 V on the HPP.

Where to buy

$300 at the Anker SOLIX store, Oct 28, 2026
BuyAmazon
$4,000 at the Goal Zero store, Oct 28, 2026
Buy

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the Yeti PRO 4000

→EcoFlow 400W Portable Solar Panel, about 800 W with two
→Anker SOLIX PS400 Bifacial, about 800 W with two
→BLUETTI PV350D, about 700 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two

All 33 panels checked against the Yeti PRO 4000

Rules we applied
  • Goal Zero Yeti PRO 4000: solar input 13.3 to 150 V on the Solar in 1 (HPP). Goal Zero does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 25.9 V becomes 28.4 V.
  • Current over the 30 A cap is safe: the station takes 30 A and you get fewer watts. We count only the capped watts.
  • Max 3,000 W on this input, 3,000 W across all inputs.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
  • Some numbers for Anker SOLIX PS100 Bifacial come from a shop listing we have not confirmed in the manual yet.
Sources
Shop listing, not yet confirmedPS100 Bifacial label values
Checked Oct 28, 2026