We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the BLUETTI PV350D work with the Goal Zero Yeti PRO 4000?

Yes. One BLUETTI PV350D works with the Goal Zero Yeti PRO 4000: about 36.1 V on a 20°F morning against the station's 150 V limit, and about 350 W in full sun. Two panels: works (2 panels in parallel on HPP), about 700 W.

Verdict

Works

1 x PV350D into the Yeti PRO 4000 (1 panel on HPP) stays inside 13.3 to 150 V and under 30 A, even at 20F.

1 x PV350D1 panel on HPP
Yeti PRO 4000HPP
Expected
350W
Voltage at 20F
36.1V
limit 150 V
Current
12.7A
cap 30 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Cables to buy
  • The panel's plug type is not confirmed yet. Check the label or the box before buying a cable.
BLUETTI PV350D

350 W, open-circuit 33 V, short-circuit 13.8 A, working 27.6 V / 12.7 A. Manual Panel details

Goal Zero Yeti PRO 4000

Solar input HPP: 13.3 to 150 V; 8mm: 12.3 to 28 V, 3000 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on HPP
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
HPP36.125.4700Works
2 panels in series on HPP
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
HPP72.312.7700Works
1 panel on HPP + 1 panel on 8mm
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
HPP + 8mm36.112.70Don't connect
2 panels in parallel on 8mm
Open-circuit voltage 33V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
8mm36.125.40Don't connect
2 panels in series on 8mm
Open-circuit voltage 66V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
8mm72.312.70Don't connect

Quick answers

Will the BLUETTI PV350D work with the Goal Zero Yeti PRO 4000?

Yes. One BLUETTI PV350D works with the Goal Zero Yeti PRO 4000: about 36.1 V on a 20°F morning against the station's 150 V limit, and about 350 W in full sun. Two panels: works (2 panels in parallel on HPP), about 700 W.

Can I connect two PV350D panels to the Yeti PRO 4000?

Yes, 2 panels in parallel on HPP. That gives about 700 W.

What cable do I need to connect the PV350D to the Yeti PRO 4000?

The panel's plug type is not confirmed yet. Check the label or the box before buying a cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PV350D goes from 33 V on its label to about 36.1 V at 20°F and 37.2 V at 0°F. The Yeti PRO 4000 accepts up to 150 V on the HPP.

Where to buy

Price not checked yet
$4,000 at the Goal Zero store, Oct 28, 2026
Buy

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the Yeti PRO 4000

→EcoFlow 400W Portable Solar Panel, about 800 W with two
→Anker SOLIX PS400 Bifacial, about 800 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two

All 33 panels checked against the Yeti PRO 4000

Rules we applied
  • Goal Zero Yeti PRO 4000: solar input 13.3 to 150 V on the Solar in 1 (HPP). Goal Zero does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 33 V becomes 36.1 V.
  • Current over the 30 A cap is safe: the station takes 30 A and you get fewer watts. We count only the capped watts.
  • Max 3,000 W on this input, 3,000 W across all inputs.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
From the manualPV350D label values
Checked Oct 28, 2026