Will the Anker SOLIX PS400 Bifacial work with the Goal Zero Yeti PRO 4000?
Yes. One Anker SOLIX PS400 Bifacial works with the Goal Zero Yeti PRO 4000: about 63.1 V on a 20°F morning against the station's 150 V limit, and about 400 W in full sun. Two panels: works (2 panels in parallel on HPP), about 800 W.
Works
1 x PS400 Bifacial into the Yeti PRO 4000 (1 panel on HPP) stays inside 13.3 to 150 V and under 30 A, even at 20F.
- The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
- 57.6 V open circuit: above the 55-60 V limit of many smaller stations even as a single panel on a cold morning.
- Needs an MC4 to HPP (Anderson Powerpole) adapter cable.
400 W, open-circuit 57.6 V, short-circuit 8.8 A, working 48 V / 8.3 A. Unconfirmed Panel details
Goal Zero Yeti PRO 4000Solar input HPP: 13.3 to 150 V; 8mm: 12.3 to 28 V, 3000 W max. Brand page Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in parallel on HPP The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | HPP | 63.1 | 16.7 | 800 | Works |
| 2 panels in series on HPP The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | HPP | 126.1 | 8.3 | 800 | Works |
| 1 panel on HPP + 1 panel on 8mm The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | HPP + 8mm | 63.1 | 8.3 | 0 | Don't connect |
| 2 panels in parallel on 8mm Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it. | 8mm | 63.1 | 16.7 | 0 | Don't connect |
| 2 panels in series on 8mm Open-circuit voltage 115.2V is above the station's 28V limit. Going over a station's input voltage limit can damage it. | 8mm | 126.1 | 8.3 | 0 | Don't connect |
Quick answers
Will the Anker SOLIX PS400 Bifacial work with the Goal Zero Yeti PRO 4000?
Yes. One Anker SOLIX PS400 Bifacial works with the Goal Zero Yeti PRO 4000: about 63.1 V on a 20°F morning against the station's 150 V limit, and about 400 W in full sun. Two panels: works (2 panels in parallel on HPP), about 800 W.
Can I connect two PS400 Bifacial panels to the Yeti PRO 4000?
Yes, 2 panels in parallel on HPP. That gives about 800 W.
What cable do I need to connect the PS400 Bifacial to the Yeti PRO 4000?
Needs an MC4 to HPP (Anderson Powerpole) adapter cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One PS400 Bifacial goes from 57.6 V on its label to about 63.1 V at 20°F and 65 V at 0°F. The Yeti PRO 4000 accepts up to 150 V on the HPP.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the Yeti PRO 4000
- Goal Zero Yeti PRO 4000: solar input 13.3 to 150 V on the Solar in 1 (HPP). Goal Zero does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 57.6 V becomes 63.1 V.
- Current over the 30 A cap is safe: the station takes 30 A and you get fewer watts. We count only the capped watts.
- Max 3,000 W on this input, 3,000 W across all inputs.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
- Some numbers for Anker SOLIX PS400 Bifacial come from a shop listing we have not confirmed in the manual yet.