We may earn a commission if you buy through these links. It never changes a verdict. How this works
BLUETTI SP200L Solar Panel
BLUETTI

SP200L Solar Panel

200 W panel with an MC4 plug. Expect about 140 W at midday in clear sun.

Where to buyPrices checked Oct 28, 2026
BLUETTI store
$50 off the store's usual $399
$349Buy
Amazon
This panel's Amazon page; price shown on Amazon
Check price

We may earn a commission if you buy through these links. It never changes a verdict.

The four numbers on the label

Every panel has a sticker on the back with these. The station cares about the first two most.

VocBrand page
24.6 V
Open-circuit voltage

The highest voltage the panel makes, with nothing plugged in. This must stay under the station's limit, including on cold mornings.

IscBrand page
10.8 A
Short-circuit current

The most current it can push. Stations cap current; over the cap you lose watts, or on some brands it is not allowed.

VmpBrand page
not on listing
Voltage at max power

The working voltage while charging. Must be above the station's minimum or charging will not start.

ImpBrand page
not on listing
Current at max power

The working current while charging. Vmp times Imp is roughly the rated watts.

Open-circuit voltage by morning temperatureone panel, -0.30%/°C, typical value, not published for this panel
28.2 V-10F
27.3 V10F
26.4 V32F
25.7 V50F
24.6 V77F

Why it matters: a station's input limit is a hard number. Two of these panels in series on a 10F morning make 54.7 V. That is fine for a 60 V input and not for a 27 V one.

Which stations it works with

One panel, 20F morning. 71 take it cleanly, 9 with a catch. Tap a row for the wiring and cables.

EcoFlow RIVER 3 PlusAbout 200 W into the XT60i. Use an MC4 to XT60i solar cable.
Works
EcoFlow DELTA 3 PlusAbout 200 W into the XT60i. Use an MC4 to XT60i solar cable.
Works
EcoFlow DELTA Pro 3About 200 W into the XT60i (Low-PV). Use an MC4 to XT60i solar cable.
Works
BLUETTI AC70About 200 W into the XT60 (XT60PM-M). Use an MC4 to XT60 solar cable.
Works
BLUETTI AC180About 200 W into the DC7909. Use an MC4 to DC7909 solar cable; check whether one came in the box.
Works
BLUETTI AC200LAbout 200 W into the DC input (via DC input cable + solar charging cable). Use the solar charging cable that came with the station (MC4 on the panel side).
Works
Anker SOLIX C1000 Gen 2The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
EcoFlow RIVER 2 MaxAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
Show all 109 stationsShow fewer
EcoFlow RIVER 2 Max 500About 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow RIVER 2 ProAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow DELTA 3The manual or page does not give a current limit for this input, so current was not checked.
Works
EcoFlow DELTA 2 MaxAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow DELTA ProAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow DELTA miniAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow DELTA 1300 (1260Wh)About 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
EcoFlow DELTA 1000About 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI EB3AAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC2AAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Pioneer 50 (AC60)About 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Pioneer MD (AC180T)The manual or page does not give a current limit for this input, so current was not checked.
Works
BLUETTI Pioneer 150 (AC240)About 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Apex 300About 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC180PAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC200MAXAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC200P LAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC50BAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC50PAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI AC70PAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI EB70SAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI EP500ProAbout 200 W into the PV input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 30 V2About 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 100 V2About 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 100 miniAbout 200 W into the DC input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 200 V2About 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 300About 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 400About 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI PS72The manual or page does not give a current limit for this input, so current was not checked.
Works
BLUETTI Pioneer NaAbout 200 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Premium 100 V2About 200 W into the DC input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Premium 200 V2About 200 W into the PV input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
Anker SOLIX C1000XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX C2000 Gen 2The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX F1500The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX F2600The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX F3000The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX F3800 PlusThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery Explorer 1000The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery Explorer 1500 v2About 200 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
Jackery Explorer 1500 UltraAbout 200 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
Jackery Explorer 2000 v2The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 300The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 500The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 700The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 1500The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti PRO 4000The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 1000XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 1500XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 3000XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Goal Zero Yeti 6000XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
EcoFlow RIVER 2About 110 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
Jackery Explorer 300 PlusThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
EcoFlow RIVER miniAbout 100 W into the DC input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
BLUETTI Elite 10 MiniAbout 100 W into the Solar input. Use the solar charging cable that came with the station (MC4 on the panel side).
Works
Anker SOLIX C200 DCThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX C200XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX C300The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX C300 DCThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Anker SOLIX C300XThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery Explorer 100 PlusThe brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Works
Jackery Explorer 300 v2About 100 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
Jackery Explorer 300DAbout 100 W into the DC8020. Needs an MC4 to DC8020 adapter cable.
Works
Jackery Explorer 1000 v2The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed.
Works, with a catch
Jackery Explorer 2000 PlusThe panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed.
Works, with a catch
EcoFlow RIVER MaxFine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage.
Works, with a catch
EcoFlow RIVER Max PlusFine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage.
Works, with a catch
EcoFlow RIVER PlusFine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage.
Works, with a catch
EcoFlow RIVERFine in mild weather (24.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.9V, above the 25V limit. Cold makes panels push more voltage.
Works, with a catch
Jackery Explorer 1000 PlusThe panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed.
Works, with a catch
Jackery Explorer 5000 PlusThe panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed.
Works, with a catch
Jackery HomePower 3000The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed.
Works, with a catch
EcoFlow DELTA Pro UltraOpen-circuit voltage 24.6V is below the 80V minimum for this input, so it will not start charging.
Don't connect
EcoFlow DELTA Pro Ultra XOpen-circuit voltage 24.6V is below the 80V minimum for this input, so it will not start charging.
Don't connect
BLUETTI AC200POpen-circuit voltage 24.6V is below the 35V minimum for this input, so it will not start charging.
Don't connect
BLUETTI EP500Open-circuit voltage 24.6V is below the 55V minimum for this input, so it will not start charging.
Don't connect
Goal Zero Yeti 500XOpen-circuit voltage 24.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it.
Don't connect
Goal Zero Yeti 200XOpen-circuit voltage 24.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it.
Don't connect
EcoFlow TRAIL 200 DCNot enough confirmed numbers to check yet.
EcoFlow TRAIL 300 DCNot enough confirmed numbers to check yet.
EcoFlow TRAIL Plus 300 DCNot enough confirmed numbers to check yet.
EcoFlow DELTA 3 ClassicNot enough confirmed numbers to check yet.
EcoFlow DELTA 3 MaxNot enough confirmed numbers to check yet.
EcoFlow DELTA 3 Max PlusNot enough confirmed numbers to check yet.
EcoFlow DELTA 3 UltraNot enough confirmed numbers to check yet.
EcoFlow DELTA 3 Ultra PlusNot enough confirmed numbers to check yet.
EcoFlow RIVER ProNot enough confirmed numbers to check yet.
BLUETTI Handsfree 1Not enough confirmed numbers to check yet.
BLUETTI Handsfree 2Not enough confirmed numbers to check yet.
Anker SOLIX C200X DCNot enough confirmed numbers to check yet.
Anker SOLIX C1000X Gen 2Not enough confirmed numbers to check yet.
Anker SOLIX S2000Not enough confirmed numbers to check yet.
Anker SOLIX S5000Not enough confirmed numbers to check yet.
Jackery Explorer 240 v2Not enough confirmed numbers to check yet.
Jackery Explorer 300Not enough confirmed numbers to check yet.
Jackery Explorer 600 v2Not enough confirmed numbers to check yet.
Jackery HomePower 1000 v2Not enough confirmed numbers to check yet.
Jackery HomePower 1000 Plus v2Not enough confirmed numbers to check yet.
Jackery HomePower 2000 Plus v2Not enough confirmed numbers to check yet.
Jackery HomePower 3600 PlusNot enough confirmed numbers to check yet.
Jackery HomePower 3600 Pro MaxNot enough confirmed numbers to check yet.

Quick answers

Which power stations work with the BLUETTI SP200L Solar Panel?

Of the 86 power stations we can check, 71 take one BLUETTI SP200L Solar Panel cleanly, even on a 20°F morning (for example the EcoFlow RIVER 3 Plus, EcoFlow DELTA 3 Plus, EcoFlow DELTA Pro 3); 9 more work with a catch, such as going over the voltage limit on cold mornings.

What is the open-circuit voltage of the BLUETTI SP200L Solar Panel?

24.6 V on the label (standard test conditions). It rises in the cold: about 26.9 V at 20°F and 27.8 V at 0°F, so check it against your station's limit on your coldest morning.

Can I wire two BLUETTI SP200L Solar Panel panels in series?

In series the voltages add: two make about 49.2 V open-circuit (53.9 V at 20°F). In parallel the currents add: about 21.6 A. Your station must accept whichever you choose.

How much does the BLUETTI SP200L Solar Panel weigh?

17.15 lb, a folding portable panel.

Sources

From the brand's pageLabel values from BLUETTI's product page. We will update once we have the manual. Price from the brand store on Oct 28, 2026.bluettipower.com