Will the Rich Solar MEGA 200 PRO (24V) work with the Goal Zero Yeti PRO 4000?

Yes. One Rich Solar MEGA 200 PRO (24V) works with the Goal Zero Yeti PRO 4000: about 47.6 V on a 20°F morning against the station's 150 V limit, and about 200 W in full sun. Two panels: works (2 panels in parallel on HPP), about 400 W.

Verdict

Works

1 x MEGA 200 PRO (24V) into the Yeti PRO 4000 (1 panel on HPP) stays inside 13.3 to 150 V and under 30 A, even at 20F.

1 x MEGA 200 PRO (24V)1 panel on HPP
Yeti PRO 4000HPP
Expected
200W
Voltage at 20F
47.6V
limit 150 V
Current
5.5A
cap 30 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • A 24 V panel: 43.5 V open circuit on its own, so two in series (87 V) only suit high-voltage solar inputs.
Cables to buy
  • Needs an MC4 to HPP (Anderson Powerpole) adapter cable.
Rich Solar MEGA 200 PRO (24V)

200 W, open-circuit 43.5 V, short-circuit 5.9 A, working 36.3 V / 5.5 A. Brand page Panel details

Goal Zero Yeti PRO 4000

Solar input HPP: 13.3 to 150 V; 8mm: 12.3 to 28 V, 3000 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on HPP
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
HPP47.611400Works
2 panels in series on HPP
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
HPP95.35.5400Works
1 panel on HPP + 1 panel on 8mm
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
HPP + 8mm47.65.50Don't connect
2 panels in parallel on 8mm
Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
8mm47.6110Don't connect
2 panels in series on 8mm
Open-circuit voltage 87V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
8mm95.35.50Don't connect

Quick answers

Will the Rich Solar MEGA 200 PRO (24V) work with the Goal Zero Yeti PRO 4000?

Yes. One Rich Solar MEGA 200 PRO (24V) works with the Goal Zero Yeti PRO 4000: about 47.6 V on a 20°F morning against the station's 150 V limit, and about 200 W in full sun. Two panels: works (2 panels in parallel on HPP), about 400 W.

Can I connect two MEGA 200 PRO (24V) panels to the Yeti PRO 4000?

Yes, 2 panels in parallel on HPP. That gives about 400 W.

What cable do I need to connect the MEGA 200 PRO (24V) to the Yeti PRO 4000?

Needs an MC4 to HPP (Anderson Powerpole) adapter cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One MEGA 200 PRO (24V) goes from 43.5 V on its label to about 47.6 V at 20°F and 49.1 V at 0°F. The Yeti PRO 4000 accepts up to 150 V on the HPP.

Where to buy

$250 at the Rich Solar store, Oct 28, 2026
Buy
$4,000 at the Goal Zero store, Oct 28, 2026
Buy

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the Yeti PRO 4000

→EcoFlow 400W Portable Solar Panel, about 800 W with two
→Anker SOLIX PS400 Bifacial, about 800 W with two
→BLUETTI PV350D, about 700 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two

All 33 panels checked against the Yeti PRO 4000

Rules we applied
  • Goal Zero Yeti PRO 4000: solar input 13.3 to 150 V on the Solar in 1 (HPP). Goal Zero does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 43.5 V becomes 47.6 V.
  • Current over the 30 A cap is safe: the station takes 30 A and you get fewer watts. We count only the capped watts.
  • Max 3,000 W on this input, 3,000 W across all inputs.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.