We may earn a commission if you buy through these links. It never changes a verdict. How this works

Will the Renogy 250W N-Type Bifacial Solar Panel work with the EcoFlow DELTA Pro 3?

Yes. One Renogy 250W N-Type Bifacial Solar Panel works with the EcoFlow DELTA Pro 3: about 24.5 V on a 20°F morning against the station's 60 V limit, and about 250 W in full sun. Two panels: works (2 panels in series on XT60 (High-PV)), about 500 W.

Verdict

Works

1 x 250W N-Type Bifacial Solar Panel into the DELTA Pro 3 (1 panel on XT60i (Low-PV)) stays inside 11 to 60 V and under 20 A, even at 20F.

1 x 250W N-Type Bifacial Solar Panel1 panel on XT60i (Low-PV)
DELTA Pro 3XT60i (Low-PV)
Expected
250W
Voltage at 20F
24.5V
limit 60 V
Current
12.8A
cap 20 A
  • The two solar inputs are different. High-PV takes 30 to 150V, Low-PV takes 11 to 60V. A single small panel is too low for High-PV and will not charge there.
  • EcoFlow's manual: panel voltage rises in cold weather, so keep a margin below the limit when wiring in series.
  • For parallel wiring you need Y-branch (T-branch) solar cables.
Cables to buy
  • Use an MC4 to XT60i solar cable.
Renogy 250W N-Type Bifacial Solar Panel

250 W, open-circuit 22.4 V, short-circuit 13.5 A, working 19.5 V / 12.8 A. Brand page Panel details

EcoFlow DELTA Pro 3

Solar input XT60 (High-PV): 30 to 150 V; XT60i (Low-PV): 11 to 60 V, 2600 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in series on XT60 (High-PV)
Best option
XT60 (High-PV)48.912.8500Works
2 panels in series on XT60i (Low-PV)
XT60i (Low-PV)48.912.8500Works
2 panels in parallel on XT60i (Low-PV)
The panels can push 25.6A but this input takes 20A, so the station caps it. Safe, you just lose some watts.
XT60i (Low-PV)24.525.6390Works
1 panel on XT60 (High-PV) + 1 panel on XT60i (Low-PV)
Open-circuit voltage 22.4V is below the 30V minimum for this input, so it will not start charging.
XT60 (High-PV) + XT60i (Low-PV)24.512.80Don't connect
2 panels in parallel on XT60 (High-PV)
Open-circuit voltage 22.4V is below the 30V minimum for this input, so it will not start charging.
XT60 (High-PV)24.525.60Don't connect

Quick answers

Will the Renogy 250W N-Type Bifacial Solar Panel work with the EcoFlow DELTA Pro 3?

Yes. One Renogy 250W N-Type Bifacial Solar Panel works with the EcoFlow DELTA Pro 3: about 24.5 V on a 20°F morning against the station's 60 V limit, and about 250 W in full sun. Two panels: works (2 panels in series on XT60 (High-PV)), about 500 W.

Can I connect two 250W N-Type Bifacial Solar Panel panels to the DELTA Pro 3?

Yes, 2 panels in series on XT60 (High-PV). That gives about 500 W.

What cable do I need to connect the 250W N-Type Bifacial Solar Panel to the DELTA Pro 3?

Use an MC4 to XT60i solar cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One 250W N-Type Bifacial Solar Panel goes from 22.4 V on its label to about 24.5 V at 20°F and 25.2 V at 0°F. The DELTA Pro 3 accepts up to 60 V on the XT60i (Low-PV).

Where to buy

$265 at the Renogy store, Oct 28, 2026
BuyAmazon
$2,799 at the EcoFlow store, Oct 28, 2026
BuyAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the DELTA Pro 3

→EcoFlow 400W Portable Solar Panel, about 800 W with two
→Anker SOLIX PS400 Bifacial, about 800 W with two
→BLUETTI PV350D, about 700 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two

All 33 panels checked against the DELTA Pro 3

Rules we applied
  • EcoFlow DELTA Pro 3: solar input 11 to 60 V on the Solar in 2 (XT60i (Low-PV)). EcoFlow sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 22.4 V becomes 24.5 V.
  • Current over the 20 A cap is safe: the station takes 20 A and you get fewer watts. We count only the capped watts.
  • Max 1,000 W on this input, 2,600 W across all inputs.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
Checked Oct 28, 2026