Will the Anker SOLIX PS100 Bifacial work with the Anker SOLIX S2000?

Yes. One Anker SOLIX PS100 Bifacial works with the Anker SOLIX S2000: about 28.4 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60i), about 200 W.

Verdict

Works

1 x PS100 Bifacial into the S2000 (1 panel on XT60i) stays inside 11 to 60 V and under 12.5 A, even at 20F.

1 x PS100 Bifacial1 panel on XT60i
S2000XT60i
Expected
100W
Voltage at 20F
28.4V
limit 60 V
Current
4.6A
cap 12.5 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Cables to buy
  • Use an MC4 to XT60i solar cable.
Anker SOLIX PS100 Bifacial

100 W, open-circuit 25.9 V, short-circuit 4.9 A, working 21.6 V / 4.6 A. Unconfirmed Panel details

Anker SOLIX S2000

Solar input XT60i: 11 to 60 V, 400 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on XT60i
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
XT60i28.49.3200Works
2 panels in series on XT60i
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
XT60i56.74.6200Works

Quick answers

Will the Anker SOLIX PS100 Bifacial work with the Anker SOLIX S2000?

Yes. One Anker SOLIX PS100 Bifacial works with the Anker SOLIX S2000: about 28.4 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60i), about 200 W.

Can I connect two PS100 Bifacial panels to the S2000?

Yes, 2 panels in parallel on XT60i. That gives about 200 W.

What cable do I need to connect the PS100 Bifacial to the S2000?

Use an MC4 to XT60i solar cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PS100 Bifacial goes from 25.9 V on its label to about 28.4 V at 20°F and 29.2 V at 0°F. The S2000 accepts up to 60 V on the XT60i.

Where to buy

$300 at the Anker SOLIX store, Oct 28, 2026
BuyAmazon
$1,000 at the Anker SOLIX store, Oct 28, 2026
BuyAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the S2000

→Jackery SolarSaga 200 (JS-200E), about 400 W with two
→Jackery SolarSaga 200 (JS-200D), about 400 W with two
→EcoFlow 400W Portable Solar Panel, about 400 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 400 W with two
→BLUETTI SP200L Solar Panel, about 400 W with two

All 33 panels checked against the S2000

Rules we applied
  • Anker SOLIX S2000: solar input 11 to 60 V on the Solar in (XT60i). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 25.9 V becomes 28.4 V.
  • Current over the 12.5 A cap is safe: the station takes 12.5 A and you get fewer watts. We count only the capped watts.
  • Max 400 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
  • Some numbers for Anker SOLIX PS100 Bifacial come from a shop listing we have not confirmed in the manual yet.
Sources
Shop listing, not yet confirmedPS100 Bifacial label values
Checked Oct 28, 2026