Will the Anker SOLIX PS400 Bifacial work with the Jackery HomePower 3600 Pro Max?

Yes, with a catch. On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V. Two panels: works, with a catch (1 panel on DC8020 + 1 panel on DC8020), about 800 W.

Verdict

Works, with a catch

It charges, but read the note. Best option: 1 panel on DC8020.

1 x PS400 Bifacial1 panel on DC8020
HomePower 3600 Pro MaxDC8020
Expected
400W
Voltage at 20F
63.1V
limit 60 V
Current
8.3A
cap 12 A
  • On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V.
  • 57.6 V open circuit: above the 55-60 V limit of many smaller stations even as a single panel on a cold morning.
Cables to buy
  • Needs an MC4 to DC8020 adapter cable.
Anker SOLIX PS400 Bifacial

400 W, open-circuit 57.6 V, short-circuit 8.8 A, working 48 V / 8.3 A. Unconfirmed Panel details

Jackery HomePower 3600 Pro Max

Solar input DC8020: 16 to 60 V; DC8020: 16 to 60 V, 1200 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
1 panel on DC8020 + 1 panel on DC8020
On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V.
DC8020 + DC802063.18.3800Works, with a catch
2 panels in parallel on DC8020
On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V.
DC802063.116.7576Works, with a catch
2 panels in series on DC8020
Working voltage 96V is above the station's 60V limit.
DC8020126.18.30Don't connect

Quick answers

Will the Anker SOLIX PS400 Bifacial work with the Jackery HomePower 3600 Pro Max?

Yes, with a catch. On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V. Two panels: works, with a catch (1 panel on DC8020 + 1 panel on DC8020), about 800 W.

Can I connect two PS400 Bifacial panels to the HomePower 3600 Pro Max?

Yes, 1 panel on DC8020 + 1 panel on DC8020. That gives about 800 W, with one catch: On a 20°F (-7°C) morning the open-circuit voltage can reach about 63.1V, above 60V..

What cable do I need to connect the PS400 Bifacial to the HomePower 3600 Pro Max?

Needs an MC4 to DC8020 adapter cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PS400 Bifacial goes from 57.6 V on its label to about 63.1 V at 20°F and 65 V at 0°F. The HomePower 3600 Pro Max accepts up to 60 V on the DC8020.

Where to buy

$700 at the Anker SOLIX store, Oct 28, 2026
BuyAmazon
$2,099 at the Jackery store, Oct 28, 2026
BuyAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the HomePower 3600 Pro Max

→EcoFlow 400W Portable Solar Panel, about 800 W with two
→BLUETTI PV350D, about 662 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 468 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two

All 33 panels checked against the HomePower 3600 Pro Max

Rules we applied
  • Jackery HomePower 3600 Pro Max: solar input 16 to 60 V on the Solar in 1 (DC8020). Jackery rates this input by working voltage (Vmp), so that is the number we hold to the limit. We still warn when the cold-morning open-circuit voltage goes over it.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 57.6 V becomes 63.1 V.
  • Current over the 12 A cap is safe: the station takes 12 A and you get fewer watts. We count only the capped watts.
  • Max 600 W on this input, 1,200 W across all inputs.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
  • Some numbers for Anker SOLIX PS400 Bifacial come from a shop listing we have not confirmed in the manual yet.
Sources
Shop listing, not yet confirmedPS400 Bifacial label values
Checked Oct 28, 2026