Will the Rich Solar MEGA 200 PRO FLEX (24V) work with the Jackery Explorer 1000?
No. Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on DC input), about 0 W.
Don't connect
Do not plug this in. Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it.
- Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it.
- The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
- A 24 V panel: 40.8 V open circuit on its own, so two in series only suit high-voltage solar inputs.
200 W, open-circuit 40.8 V, short-circuit 6.2 A, working 34.2 V / 5.9 A. Brand page Panel details
Jackery Explorer 1000Solar input DC input: 12 to 30 V. Brand page Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in parallel on DC input Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it. | DC input | 44.7 | 11.7 | 0 | Don't connect |
| 2 panels in series on DC input Open-circuit voltage 81.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it. | DC input | 89.4 | 5.9 | 0 | Don't connect |
Quick answers
Will the Rich Solar MEGA 200 PRO FLEX (24V) work with the Jackery Explorer 1000?
No. Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on DC input), about 0 W.
Can I connect two MEGA 200 PRO FLEX (24V) panels to the Explorer 1000?
No: Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it.
Is it safe on a cold morning?
Panel voltage rises in the cold. One MEGA 200 PRO FLEX (24V) goes from 40.8 V on its label to about 44.7 V at 20°F and 46 V at 0°F. The Explorer 1000 accepts up to 30 V on the DC input.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the Explorer 1000
- Jackery Explorer 1000: solar input 12 to 30 V on the Solar in (DC input). Jackery does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 40.8 V becomes 44.7 V.
- Current over the 7.5 A cap is safe: the station takes 7.5 A and you get fewer watts. We count only the capped watts.
- Max watts on this input: not confirmed yet.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.