We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the Renogy 250W N-Type Bifacial Solar Panel work with the Goal Zero Yeti 300?

Yes. One Renogy 250W N-Type Bifacial Solar Panel works with the Goal Zero Yeti 300: about 24.5 V on a 20°F morning against the station's 28 V limit, and about 195 W in full sun. Two panels: works (2 panels in parallel on 8mm), about 195 W.

Verdict

Works

1 x 250W N-Type Bifacial Solar Panel into the Yeti 300 (1 panel on 8mm) stays inside 12.3 to 28 V, even at 20F. The station caps the current at 10 A.

1 x 250W N-Type Bifacial Solar Panel1 panel on 8mm
Yeti 3008mm
Expected
195W
Voltage at 20F
24.5V
limit 28 V
Current
12.8A
cap 10 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • The panels can push 12.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts.
  • Goal Zero says a 200 W panel needs its HPP to 8mm connector for this station.
Cables to buy
  • Needs an MC4 to 8mm adapter cable.
Renogy 250W N-Type Bifacial Solar Panel

250 W, open-circuit 22.4 V, short-circuit 13.5 A, working 19.5 V / 12.8 A. Brand page Panel details

Goal Zero Yeti 300

Solar input 8mm: 12.3 to 28 V, 200 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on 8mm
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
8mm24.525.6195Works
2 panels in series on 8mm
Open-circuit voltage 44.7V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
8mm48.912.80Don't connect

Quick answers

Will the Renogy 250W N-Type Bifacial Solar Panel work with the Goal Zero Yeti 300?

Yes. One Renogy 250W N-Type Bifacial Solar Panel works with the Goal Zero Yeti 300: about 24.5 V on a 20°F morning against the station's 28 V limit, and about 195 W in full sun. Two panels: works (2 panels in parallel on 8mm), about 195 W.

Can I connect two 250W N-Type Bifacial Solar Panel panels to the Yeti 300?

Yes, 2 panels in parallel on 8mm. That gives about 195 W.

What cable do I need to connect the 250W N-Type Bifacial Solar Panel to the Yeti 300?

Needs an MC4 to 8mm adapter cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One 250W N-Type Bifacial Solar Panel goes from 22.4 V on its label to about 24.5 V at 20°F and 25.2 V at 0°F. The Yeti 300 accepts up to 28 V on the 8mm.

Where to buy

$265 at the Renogy store, Oct 28, 2026
BuyAmazon
Out of stock at the Goal Zero store
View at store

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the Yeti 300

→Jackery SolarSaga 200 (JS-200D), about 200 W with two
→BLUETTI PV200D, about 200 W with two
→EcoFlow 175W Rigid Solar Panel, about 200 W with two
→BLUETTI SP100L Solar Panel, about 200 W with two
→BLUETTI SP200L Solar Panel, about 200 W with two

All 33 panels checked against the Yeti 300

Rules we applied
  • Goal Zero Yeti 300: solar input 12.3 to 28 V on the Solar in (8mm). Goal Zero does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 22.4 V becomes 24.5 V.
  • Current over the 10 A cap is safe: the station takes 10 A and you get fewer watts. We count only the capped watts.
  • Max 200 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
From the brand's pageYeti 300 spec page, solar input
Checked Oct 28, 2026