We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the Rich Solar MEGA 200 PRO FLEX (24V) work with the EcoFlow RIVER 2?

No. Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on Solar input), about 0 W.

Verdict

Don't connect

Do not plug this in. Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it.

1 x MEGA 200 PRO FLEX (24V)1 panel on Solar input
RIVER 2Solar input
Expected
0W
Voltage at 20F
44.7V
limit 30 V
Current
5.9A
cap 8 A
  • Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it.
  • A 24 V panel: 40.8 V open circuit on its own, so two in series only suit high-voltage solar inputs.
Cables to buyNone. Do not connect this combination. Pick a panel with lower open-circuit voltage, or fewer in series.
Rich Solar MEGA 200 PRO FLEX (24V)

200 W, open-circuit 40.8 V, short-circuit 6.2 A, working 34.2 V / 5.9 A. Brand page Panel details

EcoFlow RIVER 2

Solar input Solar input: 11 to 30 V, 110 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on Solar input
Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it.
Solar input44.711.70Don't connect
2 panels in series on Solar input
Open-circuit voltage 81.6V is above the station's 30V limit. Going over a station's input voltage limit can damage it.
Solar input89.45.90Don't connect

Quick answers

Will the Rich Solar MEGA 200 PRO FLEX (24V) work with the EcoFlow RIVER 2?

No. Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on Solar input), about 0 W.

Can I connect two MEGA 200 PRO FLEX (24V) panels to the RIVER 2?

No: Open-circuit voltage 40.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it.

Is it safe on a cold morning?

Panel voltage rises in the cold. One MEGA 200 PRO FLEX (24V) goes from 40.8 V on its label to about 44.7 V at 20°F and 46 V at 0°F. The RIVER 2 accepts up to 30 V on the Solar input.

Where to buy

$300 at the Rich Solar store, Oct 28, 2026
Buy
$219 at the EcoFlow store, Oct 28, 2026
Buy

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the RIVER 2

→Jackery SolarSaga 200 (JS-200E), about 110 W with two
→Jackery SolarSaga 200 (JS-200D), about 110 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 110 W with two
→BLUETTI PV200D, about 110 W with two
→Anker SOLIX PS100 Bifacial, about 110 W with two

All 33 panels checked against the RIVER 2

Rules we applied
  • EcoFlow RIVER 2: solar input 11 to 30 V on the Solar in (Solar input). EcoFlow sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 40.8 V becomes 44.7 V.
  • Current over the 8 A cap is safe: the station takes 8 A and you get fewer watts. We count only the capped watts.
  • Max 110 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
From the brand's pageRIVER 2 spec page, solar input
Checked Oct 28, 2026