Will the Anker SOLIX PS100 Bifacial work with the EcoFlow DELTA Pro?
Yes. One Anker SOLIX PS100 Bifacial works with the EcoFlow DELTA Pro: about 28.4 V on a 20°F morning against the station's 150 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on Solar input), about 200 W.
Works
1 x PS100 Bifacial into the DELTA Pro (1 panel on Solar input) stays inside 11 to 150 V and under 15 A, even at 20F.
- Check the station's manual for the right solar cable.
100 W, open-circuit 25.9 V, short-circuit 4.9 A, working 21.6 V / 4.6 A. Unconfirmed Panel details
EcoFlow DELTA ProSolar input Solar input: 11 to 150 V, 1600 W max. Brand page Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in parallel on Solar input Best option | Solar input | 28.4 | 9.3 | 200 | Works |
| 2 panels in series on Solar input | Solar input | 56.7 | 4.6 | 200 | Works |
Quick answers
Will the Anker SOLIX PS100 Bifacial work with the EcoFlow DELTA Pro?
Yes. One Anker SOLIX PS100 Bifacial works with the EcoFlow DELTA Pro: about 28.4 V on a 20°F morning against the station's 150 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on Solar input), about 200 W.
Can I connect two PS100 Bifacial panels to the DELTA Pro?
Yes, 2 panels in parallel on Solar input. That gives about 200 W.
What cable do I need to connect the PS100 Bifacial to the DELTA Pro?
Check the station's manual for the right solar cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One PS100 Bifacial goes from 25.9 V on its label to about 28.4 V at 20°F and 29.2 V at 0°F. The DELTA Pro accepts up to 150 V on the Solar input.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the DELTA Pro
- EcoFlow DELTA Pro: solar input 11 to 150 V on the Solar in (Solar input). EcoFlow sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 25.9 V becomes 28.4 V.
- Current over the 15 A cap is safe: the station takes 15 A and you get fewer watts. We count only the capped watts.
- Max 1,600 W on this input.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
- Some numbers for Anker SOLIX PS100 Bifacial come from a shop listing we have not confirmed in the manual yet.