Will the EcoFlow NextGen 220W Bifacial Portable Solar Panel work with the DJI Power 500?
Yes. One EcoFlow NextGen 220W Bifacial Portable Solar Panel works with the DJI Power 500: about 23.5 V on a 20°F morning against the station's 30 V limit, and about 184 W in full sun. Two panels: works (1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2), about 300 W.
Works
1 x NextGen 220W Bifacial Portable Solar Panel into the Power 500 (1 panel on XT60, Solar Panel Adapter Module channel 1) stays inside 12 to 30 V, even at 20F. The station caps the current at 10 A.
- The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts.
- Solar needs the DJI Power Solar Panel Adapter Module (MPPT), sold separately: three XT60 inputs, each 12 to 30 V, up to 10 A and 200 W. DJI says each panel must stay under 30 V open-circuit, so most 100 W and 200 W 12 V panels fit one per input, never two in series.
- On the Power 500 the adapter delivers at most 300 W in total.
- Use an MC4 to XT60 solar cable.
220 W, open-circuit 21.5 V, short-circuit 12.4 A, working 18.4 V / 11.9 A. Brand page Panel details
DJI Power 500Solar input XT60, Solar Panel Adapter Module channel 1: 12 to 30 V; XT60, Solar Panel Adapter Module channel 2: 12 to 30 V; XT60, Solar Panel Adapter Module channel 3: 12 to 30 V, 300 W max. Brand page Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2 The panels can push 11.9A but this input takes 10A, so the station caps it. Safe, you just lose some watts. | XT60, Solar Panel Adapter Module channel 1 + XT60, Solar Panel Adapter Module channel 2 | 23.5 | 11.9 | 300 | Works |
| 2 panels in parallel on XT60, Solar Panel Adapter Module channel 1 The panels can push 23.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts. | XT60, Solar Panel Adapter Module channel 1 | 23.5 | 23.8 | 184 | Works |
| 2 panels in parallel on XT60, Solar Panel Adapter Module channel 2 The panels can push 23.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts. | XT60, Solar Panel Adapter Module channel 2 | 23.5 | 23.8 | 184 | Works |
| 2 panels in parallel on XT60, Solar Panel Adapter Module channel 3 The panels can push 23.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts. | XT60, Solar Panel Adapter Module channel 3 | 23.5 | 23.8 | 184 | Works |
| 2 panels in series on XT60, Solar Panel Adapter Module channel 1 Open-circuit voltage 43V is above the station's 30V limit. Going over a station's input voltage limit can damage it. | XT60, Solar Panel Adapter Module channel 1 | 47.1 | 11.9 | 0 | Don't connect |
| 2 panels in series on XT60, Solar Panel Adapter Module channel 2 Open-circuit voltage 43V is above the station's 30V limit. Going over a station's input voltage limit can damage it. | XT60, Solar Panel Adapter Module channel 2 | 47.1 | 11.9 | 0 | Don't connect |
| 2 panels in series on XT60, Solar Panel Adapter Module channel 3 Open-circuit voltage 43V is above the station's 30V limit. Going over a station's input voltage limit can damage it. | XT60, Solar Panel Adapter Module channel 3 | 47.1 | 11.9 | 0 | Don't connect |
Quick answers
Will the EcoFlow NextGen 220W Bifacial Portable Solar Panel work with the DJI Power 500?
Yes. One EcoFlow NextGen 220W Bifacial Portable Solar Panel works with the DJI Power 500: about 23.5 V on a 20°F morning against the station's 30 V limit, and about 184 W in full sun. Two panels: works (1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2), about 300 W.
Can I connect two NextGen 220W Bifacial Portable Solar Panel panels to the Power 500?
Yes, 1 panel on XT60, Solar Panel Adapter Module channel 1 + 1 panel on XT60, Solar Panel Adapter Module channel 2. That gives about 300 W.
What cable do I need to connect the NextGen 220W Bifacial Portable Solar Panel to the Power 500?
Use an MC4 to XT60 solar cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One NextGen 220W Bifacial Portable Solar Panel goes from 21.5 V on its label to about 23.5 V at 20°F and 24.3 V at 0°F. The Power 500 accepts up to 30 V on the XT60, Solar Panel Adapter Module channel 1.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the Power 500
- DJI Power 500: solar input 12 to 30 V on the Solar in 1 (XT60, Solar Panel Adapter Module channel 1). DJI sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 21.5 V becomes 23.5 V.
- Current over the 10 A cap is safe: the station takes 10 A and you get fewer watts. We count only the capped watts.
- Max 200 W on this input, 300 W across all inputs.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.