We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the Anker SOLIX PS100 Bifacial work with the BLUETTI AC2A?

Yes, with a catch. Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage. Two panels: works, with a catch (2 panels in parallel on Solar input), about 177 W.

Verdict

Works, with a catch

It charges, but read the note. Best option: 1 panel on Solar input.

1 x PS100 Bifacial1 panel on Solar input
AC2ASolar input
Expected
100W
Voltage at 20F
28.4V
limit 28 V
Current
4.6A
cap 8.2 A
  • Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage.
Cables to buy
  • Check the station's manual for the right solar cable.
Anker SOLIX PS100 Bifacial

100 W, open-circuit 25.9 V, short-circuit 4.9 A, working 21.6 V / 4.6 A. Unconfirmed Panel details

BLUETTI AC2A

Solar input Solar input: 12 to 28 V, 200 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on Solar input
Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage.
Solar input28.49.3177Works, with a catch
2 panels in series on Solar input
Open-circuit voltage 51.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
Solar input56.74.60Don't connect

Quick answers

Will the Anker SOLIX PS100 Bifacial work with the BLUETTI AC2A?

Yes, with a catch. Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage. Two panels: works, with a catch (2 panels in parallel on Solar input), about 177 W.

Can I connect two PS100 Bifacial panels to the AC2A?

Yes, 2 panels in parallel on Solar input. That gives about 177 W, with one catch: Fine in mild weather (25.9V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 28.4V, above the 28V limit. Cold makes panels push more voltage..

What cable do I need to connect the PS100 Bifacial to the AC2A?

Check the station's manual for the right solar cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PS100 Bifacial goes from 25.9 V on its label to about 28.4 V at 20°F and 29.2 V at 0°F. The AC2A accepts up to 28 V on the Solar input.

Where to buy

$300 at the Anker SOLIX store, Oct 28, 2026
BuyAmazon
Out of stock at the BLUETTI store
View at storeAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the AC2A

→BLUETTI SP200L Solar Panel, about 200 W with two
→EcoFlow 175W Rigid Solar Panel, about 183 W with two
→BLUETTI SP100L Solar Panel, about 168 W with two
→BLUETTI PV200D, about 167 W with two
→Renogy E.Flex 200W Portable Solar Panel, about 165 W with two

All 33 panels checked against the AC2A

Rules we applied
  • BLUETTI AC2A: solar input 12 to 28 V on the Solar in (Solar input). BLUETTI sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 25.9 V becomes 28.4 V.
  • Current over the 8.2 A cap is safe: the station takes 8.2 A and you get fewer watts. We count only the capped watts.
  • Max 200 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
  • Some numbers for Anker SOLIX PS100 Bifacial come from a shop listing we have not confirmed in the manual yet.
Sources
From the brand's pageAC2A spec page, solar input
Shop listing, not yet confirmedPS100 Bifacial label values
Checked Oct 28, 2026