Will the BLUETTI PV100 FX Flexible Solar Panel work with the Anker SOLIX S2000?

Yes. One BLUETTI PV100 FX Flexible Solar Panel works with the Anker SOLIX S2000: about 45.3 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60i), about 200 W.

Verdict

Works

1 x PV100 FX Flexible Solar Panel into the S2000 (1 panel on XT60i) stays inside 11 to 60 V and under 12.5 A, even at 20F.

1 x PV100 FX Flexible Solar Panel1 panel on XT60i
S2000XT60i
Expected
100W
Voltage at 20F
45.3V
limit 60 V
Current
3.1A
cap 12.5 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • 41.4 V open circuit is high for a 100 W panel: two in series reach 82.8 V, more than most stations take.
  • The BLUETTI US store sells it only in sets of 2 or more.
Cables to buy
  • Use an MC4 to XT60i solar cable.
BLUETTI PV100 FX Flexible Solar Panel

100 W, open-circuit 41.4 V, short-circuit 3.1 A. Brand page Panel details

Anker SOLIX S2000

Solar input XT60i: 11 to 60 V, 400 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on XT60i
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
XT60i45.36.1200Works
2 panels in series on XT60i
Open-circuit voltage 82.8V is above the station's 60V limit. Going over a station's input voltage limit can damage it.
XT60i90.73.10Don't connect

Quick answers

Will the BLUETTI PV100 FX Flexible Solar Panel work with the Anker SOLIX S2000?

Yes. One BLUETTI PV100 FX Flexible Solar Panel works with the Anker SOLIX S2000: about 45.3 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60i), about 200 W.

Can I connect two PV100 FX Flexible Solar Panel panels to the S2000?

Yes, 2 panels in parallel on XT60i. That gives about 200 W.

What cable do I need to connect the PV100 FX Flexible Solar Panel to the S2000?

Use an MC4 to XT60i solar cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PV100 FX Flexible Solar Panel goes from 41.4 V on its label to about 45.3 V at 20°F and 46.7 V at 0°F. The S2000 accepts up to 60 V on the XT60i.

Where to buy

$1,000 at the Anker SOLIX store, Oct 28, 2026
BuyAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the S2000

→Jackery SolarSaga 200 (JS-200E), about 400 W with two
→Jackery SolarSaga 200 (JS-200D), about 400 W with two
→EcoFlow 400W Portable Solar Panel, about 400 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 400 W with two
→BLUETTI SP200L Solar Panel, about 400 W with two

All 33 panels checked against the S2000

Rules we applied
  • Anker SOLIX S2000: solar input 11 to 60 V on the Solar in (XT60i). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 41.4 V becomes 45.3 V.
  • Current over the 12.5 A cap is safe: the station takes 12.5 A and you get fewer watts. We count only the capped watts.
  • Max 400 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.