We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the Rich Solar MEGA 200 PRO (24V) work with the Anker SOLIX F3000?

Yes. One Rich Solar MEGA 200 PRO (24V) works with the Anker SOLIX F3000: about 47.6 V on a 20°F morning against the station's 165 V limit, and about 200 W in full sun. Two panels: works (1 panel on High-PV + 1 panel on Low-PV), about 400 W.

Verdict

Works

1 x MEGA 200 PRO (24V) into the F3000 (1 panel on High-PV) stays inside 11 to 165 V and under 17 A, even at 20F.

1 x MEGA 200 PRO (24V)1 panel on High-PV
F3000High-PV
Expected
200W
Voltage at 20F
47.6V
limit 165 V
Current
5.5A
cap 17 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • Anker does not say whether its voltage limit is open-circuit or working voltage, so the checker uses the stricter reading.
  • The two solar inputs are different: High-PV takes 11 to 165V, Low-PV takes 11 to 60V.
  • A 24 V panel: 43.5 V open circuit on its own, so two in series (87 V) only suit high-voltage solar inputs.
Cables to buy
  • Use the solar charging cable that came with the station (MC4 on the panel side).
Rich Solar MEGA 200 PRO (24V)

200 W, open-circuit 43.5 V, short-circuit 5.9 A, working 36.3 V / 5.5 A. Brand page Panel details

Anker SOLIX F3000

Solar input High-PV: 11 to 165 V; Low-PV: 11 to 60 V, 2400 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
1 panel on High-PV + 1 panel on Low-PV
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
High-PV + Low-PV47.65.5400Works
2 panels in parallel on High-PV
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
High-PV47.611400Works
2 panels in series on High-PV
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
High-PV95.35.5400Works
2 panels in parallel on Low-PV
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
Low-PV47.611400Works
2 panels in series on Low-PV
Open-circuit voltage 87V is above the station's 60V limit. Going over a station's input voltage limit can damage it.
Low-PV95.35.50Don't connect

Quick answers

Will the Rich Solar MEGA 200 PRO (24V) work with the Anker SOLIX F3000?

Yes. One Rich Solar MEGA 200 PRO (24V) works with the Anker SOLIX F3000: about 47.6 V on a 20°F morning against the station's 165 V limit, and about 200 W in full sun. Two panels: works (1 panel on High-PV + 1 panel on Low-PV), about 400 W.

Can I connect two MEGA 200 PRO (24V) panels to the F3000?

Yes, 1 panel on High-PV + 1 panel on Low-PV. That gives about 400 W.

What cable do I need to connect the MEGA 200 PRO (24V) to the F3000?

Use the solar charging cable that came with the station (MC4 on the panel side).

Is it safe on a cold morning?

Panel voltage rises in the cold. One MEGA 200 PRO (24V) goes from 43.5 V on its label to about 47.6 V at 20°F and 49.1 V at 0°F. The F3000 accepts up to 165 V on the High-PV.

Where to buy

$250 at the Rich Solar store, Oct 28, 2026
Buy
$1,900 at the Anker SOLIX store, Oct 28, 2026
Buy

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the F3000

→EcoFlow 400W Portable Solar Panel, about 800 W with two
→Anker SOLIX PS400 Bifacial, about 800 W with two
→BLUETTI PV350D, about 700 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two

All 33 panels checked against the F3000

Rules we applied
  • Anker SOLIX F3000: solar input 11 to 165 V on the Solar in 1 (High-PV). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 43.5 V becomes 47.6 V.
  • Current over the 17 A cap is safe: the station takes 17 A and you get fewer watts. We count only the capped watts.
  • Max 1,600 W on this input, 2,400 W across all inputs.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
From the brand's pageF3000 spec page, solar input
From the brand's pageMEGA 200 PRO (24V) label values
Checked Oct 28, 2026