Will the BLUETTI PV100 FX Flexible Solar Panel work with the Anker SOLIX F3000?
Yes. One BLUETTI PV100 FX Flexible Solar Panel works with the Anker SOLIX F3000: about 45.3 V on a 20°F morning against the station's 165 V limit, and about 100 W in full sun. Two panels: works (1 panel on High-PV + 1 panel on Low-PV), about 200 W.
Works
1 x PV100 FX Flexible Solar Panel into the F3000 (1 panel on High-PV) stays inside 11 to 165 V and under 17 A, even at 20F.
- The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
- Anker does not say whether its voltage limit is open-circuit or working voltage, so the checker uses the stricter reading.
- The two solar inputs are different: High-PV takes 11 to 165V, Low-PV takes 11 to 60V.
- 41.4 V open circuit is high for a 100 W panel: two in series reach 82.8 V, more than most stations take.
- The BLUETTI US store sells it only in sets of 2 or more.
- Use the solar charging cable that came with the station (MC4 on the panel side).
100 W, open-circuit 41.4 V, short-circuit 3.1 A. Brand page Panel details
Anker SOLIX F3000Solar input High-PV: 11 to 165 V; Low-PV: 11 to 60 V, 2400 W max. Brand page Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 1 panel on High-PV + 1 panel on Low-PV The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | High-PV + Low-PV | 45.3 | 3.1 | 200 | Works |
| 2 panels in parallel on High-PV The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | High-PV | 45.3 | 6.1 | 200 | Works |
| 2 panels in series on High-PV The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | High-PV | 90.7 | 3.1 | 200 | Works |
| 2 panels in parallel on Low-PV The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | Low-PV | 45.3 | 6.1 | 200 | Works |
| 2 panels in series on Low-PV Open-circuit voltage 82.8V is above the station's 60V limit. Going over a station's input voltage limit can damage it. | Low-PV | 90.7 | 3.1 | 0 | Don't connect |
Quick answers
Will the BLUETTI PV100 FX Flexible Solar Panel work with the Anker SOLIX F3000?
Yes. One BLUETTI PV100 FX Flexible Solar Panel works with the Anker SOLIX F3000: about 45.3 V on a 20°F morning against the station's 165 V limit, and about 100 W in full sun. Two panels: works (1 panel on High-PV + 1 panel on Low-PV), about 200 W.
Can I connect two PV100 FX Flexible Solar Panel panels to the F3000?
Yes, 1 panel on High-PV + 1 panel on Low-PV. That gives about 200 W.
What cable do I need to connect the PV100 FX Flexible Solar Panel to the F3000?
Use the solar charging cable that came with the station (MC4 on the panel side).
Is it safe on a cold morning?
Panel voltage rises in the cold. One PV100 FX Flexible Solar Panel goes from 41.4 V on its label to about 45.3 V at 20°F and 46.7 V at 0°F. The F3000 accepts up to 165 V on the High-PV.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the F3000
- Anker SOLIX F3000: solar input 11 to 165 V on the Solar in 1 (High-PV). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 41.4 V becomes 45.3 V.
- Current over the 17 A cap is safe: the station takes 17 A and you get fewer watts. We count only the capped watts.
- Max 1,600 W on this input, 2,400 W across all inputs.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.