Will the Anker SOLIX PS100 Bifacial work with the Anker SOLIX F1500?

Yes. One Anker SOLIX PS100 Bifacial works with the Anker SOLIX F1500: about 28.4 V on a 20°F morning against the station's 30 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60), about 200 W.

Verdict

Works

1 x PS100 Bifacial into the F1500 (1 panel on XT60) stays inside 11 to 30 V and under 12.5 A, even at 20F.

1 x PS100 Bifacial1 panel on XT60
F1500XT60
Expected
100W
Voltage at 20F
28.4V
limit 30 V
Current
4.6A
cap 12.5 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • Anker does not say whether its voltage limit is open-circuit or working voltage, so the checker uses the stricter reading.
  • Anker's own page gives two different solar limits for this model (up to 30V and up to 60V). Until that is settled, the checker uses 30V.
Cables to buy
  • Use an MC4 to XT60 solar cable.
Anker SOLIX PS100 Bifacial

100 W, open-circuit 25.9 V, short-circuit 4.9 A, working 21.6 V / 4.6 A. Unconfirmed Panel details

Anker SOLIX F1500

Solar input XT60: 11 to 30 V, 600 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on XT60
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
XT6028.49.3200Works
2 panels in series on XT60
Open-circuit voltage 51.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it.
XT6056.74.60Don't connect

Quick answers

Will the Anker SOLIX PS100 Bifacial work with the Anker SOLIX F1500?

Yes. One Anker SOLIX PS100 Bifacial works with the Anker SOLIX F1500: about 28.4 V on a 20°F morning against the station's 30 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60), about 200 W.

Can I connect two PS100 Bifacial panels to the F1500?

Yes, 2 panels in parallel on XT60. That gives about 200 W.

What cable do I need to connect the PS100 Bifacial to the F1500?

Use an MC4 to XT60 solar cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PS100 Bifacial goes from 25.9 V on its label to about 28.4 V at 20°F and 29.2 V at 0°F. The F1500 accepts up to 30 V on the XT60.

Where to buy

$300 at the Anker SOLIX store, Oct 28, 2026
BuyAmazon
$1,200 at the Anker SOLIX store, Oct 28, 2026
Buy

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the F1500

→BLUETTI SP200L Solar Panel, about 400 W with two
→EcoFlow 175W Rigid Solar Panel, about 279 W with two
→BLUETTI PV200D, about 255 W with two
→Renogy E.Flex 200W Portable Solar Panel, about 252 W with two
→Renogy 200W Flexible Solar Panel, about 251 W with two

All 33 panels checked against the F1500

Rules we applied
  • Anker SOLIX F1500: solar input 11 to 30 V on the Solar in (XT60). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 25.9 V becomes 28.4 V.
  • Current over the 12.5 A cap is safe: the station takes 12.5 A and you get fewer watts. We count only the capped watts.
  • Max 600 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
  • Some numbers for Anker SOLIX PS100 Bifacial come from a shop listing we have not confirmed in the manual yet.