Will the Rich Solar MEGA 200 PRO (24V) work with the Anker SOLIX C300 DC?
No. Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on XT60), about 0 W.
Don't connect
Do not plug this in. Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
- Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
- The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
- Anker's manual: the panel voltage must be 11 to 28V or the station can be damaged.
- A 24 V panel: 43.5 V open circuit on its own, so two in series (87 V) only suit high-voltage solar inputs.
200 W, open-circuit 43.5 V, short-circuit 5.9 A, working 36.3 V / 5.5 A. Brand page Panel details
Anker SOLIX C300 DCSolar input XT60: 11 to 28 V, 100 W max. Manual Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in parallel on XT60 Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it. | XT60 | 47.6 | 11 | 0 | Don't connect |
| 2 panels in series on XT60 Open-circuit voltage 87V is above the station's 28V limit. Going over a station's input voltage limit can damage it. | XT60 | 95.3 | 5.5 | 0 | Don't connect |
Quick answers
Will the Rich Solar MEGA 200 PRO (24V) work with the Anker SOLIX C300 DC?
No. Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on XT60), about 0 W.
Can I connect two MEGA 200 PRO (24V) panels to the C300 DC?
No: Open-circuit voltage 43.5V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
Is it safe on a cold morning?
Panel voltage rises in the cold. One MEGA 200 PRO (24V) goes from 43.5 V on its label to about 47.6 V at 20°F and 49.1 V at 0°F. The C300 DC accepts up to 28 V on the XT60.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the C300 DC
- Anker SOLIX C300 DC: solar input 11 to 28 V on the Solar in (XT60). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 43.5 V becomes 47.6 V.
- Current over the 8.2 A cap is safe: the station takes 8.2 A and you get fewer watts. We count only the capped watts.
- Max 100 W on this input.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.