Will the Rich Solar MEGA 200 PRO FLEX (24V) work with the Anker SOLIX C300 DC?

No. Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on XT60), about 0 W.

Verdict

Don't connect

Do not plug this in. Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it.

1 x MEGA 200 PRO FLEX (24V)1 panel on XT60
C300 DCXT60
Expected
0W
Voltage at 20F
44.7V
limit 28 V
Current
5.9A
cap 8.2 A
  • Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • Anker's manual: the panel voltage must be 11 to 28V or the station can be damaged.
  • A 24 V panel: 40.8 V open circuit on its own, so two in series only suit high-voltage solar inputs.
Cables to buyNone. Do not connect this combination. Pick a panel with lower open-circuit voltage, or fewer in series.
Rich Solar MEGA 200 PRO FLEX (24V)

200 W, open-circuit 40.8 V, short-circuit 6.2 A, working 34.2 V / 5.9 A. Brand page Panel details

Anker SOLIX C300 DC

Solar input XT60: 11 to 28 V, 100 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on XT60
Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
XT6044.711.70Don't connect
2 panels in series on XT60
Open-circuit voltage 81.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
XT6089.45.90Don't connect

Quick answers

Will the Rich Solar MEGA 200 PRO FLEX (24V) work with the Anker SOLIX C300 DC?

No. Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on XT60), about 0 W.

Can I connect two MEGA 200 PRO FLEX (24V) panels to the C300 DC?

No: Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it.

Is it safe on a cold morning?

Panel voltage rises in the cold. One MEGA 200 PRO FLEX (24V) goes from 40.8 V on its label to about 44.7 V at 20°F and 46 V at 0°F. The C300 DC accepts up to 28 V on the XT60.

Where to buy

$300 at the Rich Solar store, Oct 28, 2026
Buy
Out of stock at the Anker SOLIX store
View at storeAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the C300 DC

→Jackery SolarSaga 200 (JS-200E), about 100 W with two
→Jackery SolarSaga 200 (JS-200D), about 100 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 100 W with two
→BLUETTI PV200D, about 100 W with two
→EcoFlow 100W Rigid Solar Panel, about 100 W with two

All 33 panels checked against the C300 DC

Rules we applied
  • Anker SOLIX C300 DC: solar input 11 to 28 V on the Solar in (XT60). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 40.8 V becomes 44.7 V.
  • Current over the 8.2 A cap is safe: the station takes 8.2 A and you get fewer watts. We count only the capped watts.
  • Max 100 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
Checked Oct 28, 2026