Will the BLUETTI PV120 Solar Panel work with the Anker SOLIX C300 DC?
Yes. One BLUETTI PV120 Solar Panel works with the Anker SOLIX C300 DC: about 26.7 V on a 20°F morning against the station's 28 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60), about 100 W.
Works
1 x PV120 Solar Panel into the C300 DC (1 panel on XT60) stays inside 11 to 28 V and under 8.2 A, even at 20F.
- The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
- Anker's manual: the panel voltage must be 11 to 28V or the station can be damaged.
- Use an MC4 to XT60 solar cable.
120 W, open-circuit 24.4 V, short-circuit 6.4 A, working 19.6 V / 6.1 A. Brand page Panel details
Anker SOLIX C300 DCSolar input XT60: 11 to 28 V, 100 W max. Manual Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in parallel on XT60 The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | XT60 | 26.7 | 12.2 | 100 | Works |
| 2 panels in series on XT60 Open-circuit voltage 48.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it. | XT60 | 53.4 | 6.1 | 0 | Don't connect |
Quick answers
Will the BLUETTI PV120 Solar Panel work with the Anker SOLIX C300 DC?
Yes. One BLUETTI PV120 Solar Panel works with the Anker SOLIX C300 DC: about 26.7 V on a 20°F morning against the station's 28 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60), about 100 W.
Can I connect two PV120 Solar Panel panels to the C300 DC?
Yes, 2 panels in parallel on XT60. That gives about 100 W.
What cable do I need to connect the PV120 Solar Panel to the C300 DC?
Use an MC4 to XT60 solar cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One PV120 Solar Panel goes from 24.4 V on its label to about 26.7 V at 20°F and 27.5 V at 0°F. The C300 DC accepts up to 28 V on the XT60.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the C300 DC
- Anker SOLIX C300 DC: solar input 11 to 28 V on the Solar in (XT60). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 24.4 V becomes 26.7 V.
- Current over the 8.2 A cap is safe: the station takes 8.2 A and you get fewer watts. We count only the capped watts.
- Max 100 W on this input.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.