Will the Anker SOLIX PS200 Bifacial work with the Anker SOLIX C200 DC?

No. Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on XT60), about 0 W.

Verdict

Don't connect

Do not plug this in. Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it.

1 x PS200 Bifacial1 panel on XT60
C200 DCXT60
Expected
0W
Voltage at 20F
63.1V
limit 28 V
Current
4.2A
cap 8.2 A
  • Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • Anker's manual: use only 11 to 28V panels with an XT60 plug. The PS200 and PS400 panels are not compatible and can damage it.
Cables to buyNone. Do not connect this combination. Pick a panel with lower open-circuit voltage, or fewer in series.
Anker SOLIX PS200 Bifacial

200 W, open-circuit 57.6 V, short-circuit 4.4 A, working 48 V / 4.2 A. Unconfirmed Panel details

Anker SOLIX C200 DC

Solar input XT60: 11 to 28 V, 100 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on XT60
Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
XT6063.18.30Don't connect
2 panels in series on XT60
Open-circuit voltage 115.2V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
XT60126.14.20Don't connect

Quick answers

Will the Anker SOLIX PS200 Bifacial work with the Anker SOLIX C200 DC?

No. Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on XT60), about 0 W.

Can I connect two PS200 Bifacial panels to the C200 DC?

No: Open-circuit voltage 57.6V is above the station's 28V limit. Going over a station's input voltage limit can damage it.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PS200 Bifacial goes from 57.6 V on its label to about 63.1 V at 20°F and 65 V at 0°F. The C200 DC accepts up to 28 V on the XT60.

Where to buy

$500 at the Anker SOLIX store, Oct 28, 2026
BuyAmazon
Out of stock at the Anker SOLIX store
View at storeAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the C200 DC

→Jackery SolarSaga 200 (JS-200E), about 100 W with two
→Jackery SolarSaga 200 (JS-200D), about 100 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 100 W with two
→BLUETTI PV200D, about 100 W with two
→EcoFlow 100W Rigid Solar Panel, about 100 W with two

All 33 panels checked against the C200 DC

Rules we applied
  • Anker SOLIX C200 DC: solar input 11 to 28 V on the Solar in (XT60). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 57.6 V becomes 63.1 V.
  • Current over the 8.2 A cap is safe: the station takes 8.2 A and you get fewer watts. We count only the capped watts.
  • Max 100 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
  • Some numbers for Anker SOLIX PS200 Bifacial come from a shop listing we have not confirmed in the manual yet.
Sources
Shop listing, not yet confirmedPS200 Bifacial label values
Checked Oct 28, 2026