Will the BLUETTI PV100 FX Flexible Solar Panel work with the Anker SOLIX C1000X?
Yes. One BLUETTI PV100 FX Flexible Solar Panel works with the Anker SOLIX C1000X: about 45.3 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60), about 200 W.
Works
1 x PV100 FX Flexible Solar Panel into the C1000X (1 panel on XT60) stays inside 11 to 60 V and under 10 A, even at 20F.
- The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
- Anker does not say whether its voltage limit is open-circuit or working voltage, so the checker uses the stricter reading.
- Below 32V the input takes 10A; from 32 to 60V it takes 12.5A.
- 41.4 V open circuit is high for a 100 W panel: two in series reach 82.8 V, more than most stations take.
- The BLUETTI US store sells it only in sets of 2 or more.
- Use an MC4 to XT60 solar cable.
100 W, open-circuit 41.4 V, short-circuit 3.1 A. Brand page Panel details
Anker SOLIX C1000XSolar input XT60: 11 to 60 V, 600 W max. Brand page Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in parallel on XT60 The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | XT60 | 45.3 | 6.1 | 200 | Works |
| 2 panels in series on XT60 Open-circuit voltage 82.8V is above the station's 60V limit. Going over a station's input voltage limit can damage it. | XT60 | 90.7 | 3.1 | 0 | Don't connect |
Quick answers
Will the BLUETTI PV100 FX Flexible Solar Panel work with the Anker SOLIX C1000X?
Yes. One BLUETTI PV100 FX Flexible Solar Panel works with the Anker SOLIX C1000X: about 45.3 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60), about 200 W.
Can I connect two PV100 FX Flexible Solar Panel panels to the C1000X?
Yes, 2 panels in parallel on XT60. That gives about 200 W.
What cable do I need to connect the PV100 FX Flexible Solar Panel to the C1000X?
Use an MC4 to XT60 solar cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One PV100 FX Flexible Solar Panel goes from 41.4 V on its label to about 45.3 V at 20°F and 46.7 V at 0°F. The C1000X accepts up to 60 V on the XT60.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the C1000X
- Anker SOLIX C1000X: solar input 11 to 60 V on the Solar in (XT60). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 41.4 V becomes 45.3 V.
- Current over the 10 A cap is safe: the station takes 10 A and you get fewer watts. We count only the capped watts.
- Max 600 W on this input.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.