We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the Rich Solar MEGA 200 PRO FLEX (24V) work with the Anker SOLIX C1000X Gen 2?

Yes. One Rich Solar MEGA 200 PRO FLEX (24V) works with the Anker SOLIX C1000X Gen 2: about 44.7 V on a 20°F morning against the station's 60 V limit, and about 200 W in full sun. Two panels: works (2 panels in parallel on XT60i), about 400 W.

Verdict

Works

1 x MEGA 200 PRO FLEX (24V) into the C1000X Gen 2 (1 panel on XT60i) stays inside 11 to 60 V and under 14.5 A, even at 20F.

1 x MEGA 200 PRO FLEX (24V)1 panel on XT60i
C1000X Gen 2XT60i
Expected
200W
Voltage at 20F
44.7V
limit 60 V
Current
5.9A
cap 14.5 A
  • Anker: keep the total open-circuit voltage within 60 V and the total short-circuit current within 15 A, and wire several panels in parallel, not in series.
  • A 24 V panel: 40.8 V open circuit on its own, so two in series only suit high-voltage solar inputs.
Cables to buy
  • Use an MC4 to XT60i solar cable.
Rich Solar MEGA 200 PRO FLEX (24V)

200 W, open-circuit 40.8 V, short-circuit 6.2 A, working 34.2 V / 5.9 A. Brand page Panel details

Anker SOLIX C1000X Gen 2

Solar input XT60i: 11 to 60 V, 600 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on XT60i
Best option
XT60i44.711.7400Works
2 panels in series on XT60i
Open-circuit voltage 81.6V is above the station's 60V limit. Going over a station's input voltage limit can damage it.
XT60i89.45.90Don't connect

Quick answers

Will the Rich Solar MEGA 200 PRO FLEX (24V) work with the Anker SOLIX C1000X Gen 2?

Yes. One Rich Solar MEGA 200 PRO FLEX (24V) works with the Anker SOLIX C1000X Gen 2: about 44.7 V on a 20°F morning against the station's 60 V limit, and about 200 W in full sun. Two panels: works (2 panels in parallel on XT60i), about 400 W.

Can I connect two MEGA 200 PRO FLEX (24V) panels to the C1000X Gen 2?

Yes, 2 panels in parallel on XT60i. That gives about 400 W.

What cable do I need to connect the MEGA 200 PRO FLEX (24V) to the C1000X Gen 2?

Use an MC4 to XT60i solar cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One MEGA 200 PRO FLEX (24V) goes from 40.8 V on its label to about 44.7 V at 20°F and 46 V at 0°F. The C1000X Gen 2 accepts up to 60 V on the XT60i.

Where to buy

$300 at the Rich Solar store, Oct 28, 2026
Buy
$700 at the Anker SOLIX store, Oct 28, 2026
Buy

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the C1000X Gen 2

→EcoFlow 400W Portable Solar Panel, about 595 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two
→Jackery SolarSaga 200 (JS-200D), about 400 W with two

All 33 panels checked against the C1000X Gen 2

Rules we applied
  • Anker SOLIX C1000X Gen 2: solar input 11 to 60 V on the Solar in (XT60i). Anker SOLIX sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 40.8 V becomes 44.7 V.
  • Current over the 14.5 A cap is safe: the station takes 14.5 A and you get fewer watts. We count only the capped watts.
  • Max 600 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
Checked Oct 28, 2026