Will the Rich Solar MEGA 100 work with the Anker SOLIX C1000 Gen 2?
Yes. One Rich Solar MEGA 100 works with the Anker SOLIX C1000 Gen 2: about 25 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60i), about 200 W.
Works
1 x MEGA 100 into the C1000 Gen 2 (1 panel on XT60i) stays inside 11 to 60 V and under 14.5 A, even at 20F.
- The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
- Anker's page gives 11 to 60V but does not say whether that is open-circuit or working voltage, so the checker uses the stricter reading.
- Use an MC4 to XT60i solar cable.
100 W, open-circuit 22.8 V, short-circuit 5.8 A, working 18.6 V / 5.4 A. Brand page Panel details
Anker SOLIX C1000 Gen 2Solar input XT60i: 11 to 60 V, 600 W max. Brand page Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in parallel on XT60i The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | XT60i | 25 | 10.8 | 200 | Works |
| 2 panels in series on XT60i The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | XT60i | 49.9 | 5.4 | 200 | Works |
Quick answers
Will the Rich Solar MEGA 100 work with the Anker SOLIX C1000 Gen 2?
Yes. One Rich Solar MEGA 100 works with the Anker SOLIX C1000 Gen 2: about 25 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on XT60i), about 200 W.
Can I connect two MEGA 100 panels to the C1000 Gen 2?
Yes, 2 panels in parallel on XT60i. That gives about 200 W.
What cable do I need to connect the MEGA 100 to the C1000 Gen 2?
Use an MC4 to XT60i solar cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One MEGA 100 goes from 22.8 V on its label to about 25 V at 20°F and 25.7 V at 0°F. The C1000 Gen 2 accepts up to 60 V on the XT60i.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the C1000 Gen 2
- Anker SOLIX C1000 Gen 2: solar input 11 to 60 V on the Solar in (XT60i). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 22.8 V becomes 25 V.
- Current over the 14.5 A cap is safe: the station takes 14.5 A and you get fewer watts. We count only the capped watts.
- Max 600 W on this input.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.