Will the Renogy 200W Flexible Solar Panel work with the Anker SOLIX C1000 Gen 2?
Yes. One Renogy 200W Flexible Solar Panel works with the Anker SOLIX C1000 Gen 2: about 26.2 V on a 20°F morning against the station's 60 V limit, and about 200 W in full sun. Two panels: works (2 panels in series on XT60i), about 400 W.
Works
1 x 200W Flexible Solar Panel into the C1000 Gen 2 (1 panel on XT60i) stays inside 11 to 60 V and under 14.5 A, even at 20F.
- The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
- Anker's page gives 11 to 60V but does not say whether that is open-circuit or working voltage, so the checker uses the stricter reading.
- Use an MC4 to XT60i solar cable.
200 W, open-circuit 23.9 V, short-circuit 10.7 A, working 20.1 V / 10 A. Brand page Panel details
Anker SOLIX C1000 Gen 2Solar input XT60i: 11 to 60 V, 600 W max. Brand page Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in series on XT60i The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | XT60i | 52.3 | 10 | 400 | Works |
| 2 panels in parallel on XT60i The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | XT60i | 26.2 | 20 | 291 | Works |
Quick answers
Will the Renogy 200W Flexible Solar Panel work with the Anker SOLIX C1000 Gen 2?
Yes. One Renogy 200W Flexible Solar Panel works with the Anker SOLIX C1000 Gen 2: about 26.2 V on a 20°F morning against the station's 60 V limit, and about 200 W in full sun. Two panels: works (2 panels in series on XT60i), about 400 W.
Can I connect two 200W Flexible Solar Panel panels to the C1000 Gen 2?
Yes, 2 panels in series on XT60i. That gives about 400 W.
What cable do I need to connect the 200W Flexible Solar Panel to the C1000 Gen 2?
Use an MC4 to XT60i solar cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One 200W Flexible Solar Panel goes from 23.9 V on its label to about 26.2 V at 20°F and 27 V at 0°F. The C1000 Gen 2 accepts up to 60 V on the XT60i.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the C1000 Gen 2
- Anker SOLIX C1000 Gen 2: solar input 11 to 60 V on the Solar in (XT60i). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 23.9 V becomes 26.2 V.
- Current over the 14.5 A cap is safe: the station takes 14.5 A and you get fewer watts. We count only the capped watts.
- Max 600 W on this input.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.