We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the BLUETTI PV350D work with the Anker SOLIX C1000 Gen 2?

Yes. One BLUETTI PV350D works with the Anker SOLIX C1000 Gen 2: about 36.1 V on a 20°F morning against the station's 60 V limit, and about 350 W in full sun. Two panels: works (2 panels in parallel on XT60i), about 400 W.

Verdict

Works

1 x PV350D into the C1000 Gen 2 (1 panel on XT60i) stays inside 11 to 60 V and under 14.5 A, even at 20F.

1 x PV350D1 panel on XT60i
C1000 Gen 2XT60i
Expected
350W
Voltage at 20F
36.1V
limit 60 V
Current
12.7A
cap 14.5 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • Anker's page gives 11 to 60V but does not say whether that is open-circuit or working voltage, so the checker uses the stricter reading.
Cables to buy
  • The panel's plug type is not confirmed yet. Check the label or the box before buying a cable.
BLUETTI PV350D

350 W, open-circuit 33 V, short-circuit 13.8 A, working 27.6 V / 12.7 A. Manual Panel details

Anker SOLIX C1000 Gen 2

Solar input XT60i: 11 to 60 V, 600 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on XT60i
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
XT60i36.125.4400Works
2 panels in series on XT60i
Open-circuit voltage 66V is above the station's 60V limit. Going over a station's input voltage limit can damage it.
XT60i72.312.70Don't connect

Quick answers

Will the BLUETTI PV350D work with the Anker SOLIX C1000 Gen 2?

Yes. One BLUETTI PV350D works with the Anker SOLIX C1000 Gen 2: about 36.1 V on a 20°F morning against the station's 60 V limit, and about 350 W in full sun. Two panels: works (2 panels in parallel on XT60i), about 400 W.

Can I connect two PV350D panels to the C1000 Gen 2?

Yes, 2 panels in parallel on XT60i. That gives about 400 W.

What cable do I need to connect the PV350D to the C1000 Gen 2?

The panel's plug type is not confirmed yet. Check the label or the box before buying a cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PV350D goes from 33 V on its label to about 36.1 V at 20°F and 37.2 V at 0°F. The C1000 Gen 2 accepts up to 60 V on the XT60i.

Where to buy

Price not checked yet
$700 at the Anker SOLIX store, Oct 28, 2026
BuyAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the C1000 Gen 2

→EcoFlow 400W Portable Solar Panel, about 595 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two
→Jackery SolarSaga 200 (JS-200D), about 400 W with two

All 33 panels checked against the C1000 Gen 2

Rules we applied
  • Anker SOLIX C1000 Gen 2: solar input 11 to 60 V on the Solar in (XT60i). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 33 V becomes 36.1 V.
  • Current over the 14.5 A cap is safe: the station takes 14.5 A and you get fewer watts. We count only the capped watts.
  • Max 600 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
From the manualPV350D label values
Checked Oct 28, 2026