We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the BLUETTI PV200D work with the Anker SOLIX C1000 Gen 2?

Yes. One BLUETTI PV200D works with the Anker SOLIX C1000 Gen 2: about 26.9 V on a 20°F morning against the station's 60 V limit, and about 198 W in full sun. Two panels: works (2 panels in series on XT60i), about 396 W.

Verdict

Works

1 x PV200D into the C1000 Gen 2 (1 panel on XT60i) stays inside 11 to 60 V and under 14.5 A, even at 20F.

1 x PV200D1 panel on XT60i
C1000 Gen 2XT60i
Expected
198W
Voltage at 20F
26.9V
limit 60 V
Current
9.7A
cap 14.5 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • Anker's page gives 11 to 60V but does not say whether that is open-circuit or working voltage, so the checker uses the stricter reading.
Cables to buy
  • The panel's plug type is not confirmed yet. Check the label or the box before buying a cable.
BLUETTI PV200D

200 W, open-circuit 24.6 V, short-circuit 10.8 A, working 20.4 V / 9.7 A. Manual Panel details

Anker SOLIX C1000 Gen 2

Solar input XT60i: 11 to 60 V, 600 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in series on XT60i
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
XT60i53.99.7396Works
2 panels in parallel on XT60i
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
XT60i26.919.4296Works

Quick answers

Will the BLUETTI PV200D work with the Anker SOLIX C1000 Gen 2?

Yes. One BLUETTI PV200D works with the Anker SOLIX C1000 Gen 2: about 26.9 V on a 20°F morning against the station's 60 V limit, and about 198 W in full sun. Two panels: works (2 panels in series on XT60i), about 396 W.

Can I connect two PV200D panels to the C1000 Gen 2?

Yes, 2 panels in series on XT60i. That gives about 396 W.

What cable do I need to connect the PV200D to the C1000 Gen 2?

The panel's plug type is not confirmed yet. Check the label or the box before buying a cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PV200D goes from 24.6 V on its label to about 26.9 V at 20°F and 27.8 V at 0°F. The C1000 Gen 2 accepts up to 60 V on the XT60i.

Where to buy

Price not checked yet
$700 at the Anker SOLIX store, Oct 28, 2026
BuyAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the C1000 Gen 2

→EcoFlow 400W Portable Solar Panel, about 595 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two
→Jackery SolarSaga 200 (JS-200D), about 400 W with two

All 33 panels checked against the C1000 Gen 2

Rules we applied
  • Anker SOLIX C1000 Gen 2: solar input 11 to 60 V on the Solar in (XT60i). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 24.6 V becomes 26.9 V.
  • Current over the 14.5 A cap is safe: the station takes 14.5 A and you get fewer watts. We count only the capped watts.
  • Max 600 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
From the manualPV200D label values
Checked Oct 28, 2026