Will the BLUETTI PV100 FX Flexible Solar Panel work with the Jackery HomePower 3600 Plus?
Yes. One BLUETTI PV100 FX Flexible Solar Panel works with the Jackery HomePower 3600 Plus: about 45.3 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (1 panel on DC8020 + 1 panel on DC8020), about 200 W.
Works
1 x PV100 FX Flexible Solar Panel into the HomePower 3600 Plus (1 panel on DC8020) stays inside 12 to 60 V and under 8 A, even at 20F.
- Jackery's manual: if you use both inputs, keep the voltage on both the same (same panel model, same number of panels), or the unit can be damaged.
- 41.4 V open circuit is high for a 100 W panel: two in series reach 82.8 V, more than most stations take.
- The BLUETTI US store sells it only in sets of 2 or more.
- Needs an MC4 to DC8020 adapter cable.
100 W, open-circuit 41.4 V, short-circuit 3.1 A. Brand page Panel details
Jackery HomePower 3600 PlusSolar input DC8020: 12 to 60 V; DC8020: 12 to 60 V, 1000 W max. Manual Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 1 panel on DC8020 + 1 panel on DC8020 Best option | DC8020 + DC8020 | 45.3 | 3.1 | 200 | Works |
| 2 panels in parallel on DC8020 | DC8020 | 45.3 | 6.1 | 200 | Works |
| 2 panels in series on DC8020 Open-circuit voltage 82.8V is above the station's 60V limit. Going over a station's input voltage limit can damage it. | DC8020 | 90.7 | 3.1 | 0 | Don't connect |
Quick answers
Will the BLUETTI PV100 FX Flexible Solar Panel work with the Jackery HomePower 3600 Plus?
Yes. One BLUETTI PV100 FX Flexible Solar Panel works with the Jackery HomePower 3600 Plus: about 45.3 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (1 panel on DC8020 + 1 panel on DC8020), about 200 W.
Can I connect two PV100 FX Flexible Solar Panel panels to the HomePower 3600 Plus?
Yes, 1 panel on DC8020 + 1 panel on DC8020. That gives about 200 W.
What cable do I need to connect the PV100 FX Flexible Solar Panel to the HomePower 3600 Plus?
Needs an MC4 to DC8020 adapter cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One PV100 FX Flexible Solar Panel goes from 41.4 V on its label to about 45.3 V at 20°F and 46.7 V at 0°F. The HomePower 3600 Plus accepts up to 60 V on the DC8020.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the HomePower 3600 Plus
- Jackery HomePower 3600 Plus: solar input 12 to 60 V on the Solar in 1 (DC8020). Jackery sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 41.4 V becomes 45.3 V.
- Current over the 8 A cap is safe: the station takes 8 A and you get fewer watts. We count only the capped watts.
- Max 500 W on this input, 1,000 W across all inputs.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.