We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the BLUETTI PV350D work with the Jackery HomePower 1000 v2?

Yes. One BLUETTI PV350D works with the Jackery HomePower 1000 v2: about 36.1 V on a 20°F morning against the station's 60 V limit, and about 331 W in full sun. Two panels: works (1 panel on DC8020 + 1 panel on DC8020), about 400 W.

Verdict

Works

1 x PV350D into the HomePower 1000 v2 (1 panel on DC8020) stays inside 16 to 60 V, even at 20F. The station caps the current at 12 A.

1 x PV350D1 panel on DC8020
HomePower 1000 v2DC8020
Expected
331W
Voltage at 20F
36.1V
limit 60 V
Current
12.7A
cap 12 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • The panels can push 12.7A but this input takes 12A, so the station caps it. Safe, you just lose some watts.
Cables to buy
  • The panel's plug type is not confirmed yet. Check the label or the box before buying a cable.
BLUETTI PV350D

350 W, open-circuit 33 V, short-circuit 13.8 A, working 27.6 V / 12.7 A. Manual Panel details

Jackery HomePower 1000 v2

Solar input DC8020: 16 to 60 V; DC8020: 16 to 60 V, 400 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
1 panel on DC8020 + 1 panel on DC8020
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
DC8020 + DC802036.112.7400Works
2 panels in parallel on DC8020
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
DC802036.125.4331Works
2 panels in series on DC8020
Open-circuit voltage 66V is above the station's 60V limit. Going over a station's input voltage limit can damage it.
DC802072.312.70Don't connect

Quick answers

Will the BLUETTI PV350D work with the Jackery HomePower 1000 v2?

Yes. One BLUETTI PV350D works with the Jackery HomePower 1000 v2: about 36.1 V on a 20°F morning against the station's 60 V limit, and about 331 W in full sun. Two panels: works (1 panel on DC8020 + 1 panel on DC8020), about 400 W.

Can I connect two PV350D panels to the HomePower 1000 v2?

Yes, 1 panel on DC8020 + 1 panel on DC8020. That gives about 400 W.

What cable do I need to connect the PV350D to the HomePower 1000 v2?

The panel's plug type is not confirmed yet. Check the label or the box before buying a cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PV350D goes from 33 V on its label to about 36.1 V at 20°F and 37.2 V at 0°F. The HomePower 1000 v2 accepts up to 60 V on the DC8020.

Where to buy

Price not checked yet
$549 at the Jackery store, Oct 28, 2026
BuyAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the HomePower 1000 v2

→Jackery SolarSaga 200 (JS-200E), about 400 W with two
→Jackery SolarSaga 200 (JS-200D), about 400 W with two
→EcoFlow 400W Portable Solar Panel, about 400 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 400 W with two
→BLUETTI SP200L Solar Panel, about 400 W with two

All 33 panels checked against the HomePower 1000 v2

Rules we applied
  • Jackery HomePower 1000 v2: solar input 16 to 60 V on the Solar in 1 (DC8020). Jackery does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 33 V becomes 36.1 V.
  • Current over the 12 A cap is safe: the station takes 12 A and you get fewer watts. We count only the capped watts.
  • Max 200 W on this input, 400 W across all inputs.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
From the manualPV350D label values
Checked Oct 28, 2026