Will the Rich Solar MEGA 200 PRO (24V) work with the Jackery Explorer 5000 Plus?
Yes. One Rich Solar MEGA 200 PRO (24V) works with the Jackery Explorer 5000 Plus: about 47.6 V on a 20°F morning against the station's 60 V limit, and about 200 W in full sun. Two panels: works (2 panels in parallel on Low-PV (DC8020)), about 381 W.
Works
1 x MEGA 200 PRO (24V) into the Explorer 5000 Plus (1 panel on Low-PV (DC8020)) stays inside 11 to 60 V and under 10.5 A, even at 20F.
- There are two kinds of solar input: High-PV takes 135 to 450V (panels in series), Low-PV is two DC8020 ports.
- A 24 V panel: 43.5 V open circuit on its own, so two in series (87 V) only suit high-voltage solar inputs.
- Needs an MC4 to DC8020 adapter cable.
200 W, open-circuit 43.5 V, short-circuit 5.9 A, working 36.3 V / 5.5 A. Brand page Panel details
Jackery Explorer 5000 PlusSolar input High-PV (MC4): 135 to 450 V; Low-PV (DC8020): 11 to 60 V; Low-PV (DC8020): 11 to 60 V. Manual Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in parallel on Low-PV (DC8020) The panels can push 11A but this input takes 10.5A, so the station caps it. Safe, you just lose some watts. | Low-PV (DC8020) | 47.6 | 11 | 381 | Works |
| 1 panel on High-PV (MC4) + 1 panel on Low-PV (DC8020) Open-circuit voltage 43.5V is below the 135V minimum for this input, so it will not start charging. | High-PV (MC4) + Low-PV (DC8020) | 47.6 | 5.5 | 0 | Don't connect |
| 2 panels in parallel on High-PV (MC4) Open-circuit voltage 43.5V is below the 135V minimum for this input, so it will not start charging. | High-PV (MC4) | 47.6 | 11 | 0 | Don't connect |
| 2 panels in series on High-PV (MC4) Open-circuit voltage 87V is below the 135V minimum for this input, so it will not start charging. | High-PV (MC4) | 95.3 | 5.5 | 0 | Don't connect |
| 2 panels in series on Low-PV (DC8020) Working voltage 72.6V is above the station's 60V limit. | Low-PV (DC8020) | 95.3 | 5.5 | 0 | Don't connect |
Quick answers
Will the Rich Solar MEGA 200 PRO (24V) work with the Jackery Explorer 5000 Plus?
Yes. One Rich Solar MEGA 200 PRO (24V) works with the Jackery Explorer 5000 Plus: about 47.6 V on a 20°F morning against the station's 60 V limit, and about 200 W in full sun. Two panels: works (2 panels in parallel on Low-PV (DC8020)), about 381 W.
Can I connect two MEGA 200 PRO (24V) panels to the Explorer 5000 Plus?
Yes, 2 panels in parallel on Low-PV (DC8020). That gives about 381 W.
What cable do I need to connect the MEGA 200 PRO (24V) to the Explorer 5000 Plus?
Needs an MC4 to DC8020 adapter cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One MEGA 200 PRO (24V) goes from 43.5 V on its label to about 47.6 V at 20°F and 49.1 V at 0°F. The Explorer 5000 Plus accepts up to 60 V on the Low-PV (DC8020).
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the Explorer 5000 Plus
- Jackery Explorer 5000 Plus: solar input 11 to 60 V on the Solar in 2 (Low-PV (DC8020)). Jackery rates this input by working voltage (Vmp), so that is the number we hold to the limit. We still warn when the cold-morning open-circuit voltage goes over it.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 43.5 V becomes 47.6 V.
- Current over the 10.5 A cap is safe: the station takes 10.5 A and you get fewer watts. We count only the capped watts.
- Max watts on this input: not confirmed yet.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.