We may earn a commission if you buy through these links. It never changes a verdict. How this works

Will the BLUETTI PV100 FX Flexible Solar Panel work with the Jackery Explorer 2000 Plus?

Yes, with a catch. The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed. Two panels: works, with a catch (1 panel on DC8020 + 1 panel on DC8020), about 200 W.

Verdict

Works, with a catch

It charges, but read the note. Best option: 1 panel on DC8020.

1 x PV100 FX Flexible Solar Panel1 panel on DC8020
Explorer 2000 PlusDC8020
Expected
100W
Voltage at 20F
45.3V
limit 60 V
Current
3.1A
cap 8 A
  • The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed.
  • Jackery's manual: if you use both inputs, put the same type and the same number of panels on each, or uneven voltages can cause damage or charging problems.
  • Three or four panels need Jackery's solar series connector. The manual also shows wiring methods that are not allowed, so check that page before you wire.
  • 41.4 V open circuit is high for a 100 W panel: two in series reach 82.8 V, more than most stations take.
  • The BLUETTI US store sells it only in sets of 2 or more.
Cables to buy
  • Needs an MC4 to DC8020 adapter cable.
BLUETTI PV100 FX Flexible Solar Panel

100 W, open-circuit 41.4 V, short-circuit 3.1 A. Brand page Panel details

Jackery Explorer 2000 Plus

Solar input DC8020: 11 to 60 V; DC8020: 11 to 60 V, 1400 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
1 panel on DC8020 + 1 panel on DC8020
The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed.
DC8020 + DC802045.33.1200Works, with a catch
2 panels in parallel on DC8020
The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed.
DC802045.36.1200Works, with a catch
2 panels in series on DC8020
The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed.
DC802090.73.1200Works, with a catch

Quick answers

Will the BLUETTI PV100 FX Flexible Solar Panel work with the Jackery Explorer 2000 Plus?

Yes, with a catch. The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed. Two panels: works, with a catch (1 panel on DC8020 + 1 panel on DC8020), about 200 W.

Can I connect two PV100 FX Flexible Solar Panel panels to the Explorer 2000 Plus?

Yes, 1 panel on DC8020 + 1 panel on DC8020. That gives about 200 W, with one catch: The panel's working voltage is not published, and this station is rated by working voltage, so the fit cannot be confirmed..

What cable do I need to connect the PV100 FX Flexible Solar Panel to the Explorer 2000 Plus?

Needs an MC4 to DC8020 adapter cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PV100 FX Flexible Solar Panel goes from 41.4 V on its label to about 45.3 V at 20°F and 46.7 V at 0°F. The Explorer 2000 Plus accepts up to 60 V on the DC8020.

Where to buy

Out of stock at the Jackery store
View at storeAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the Explorer 2000 Plus

→EcoFlow 400W Portable Solar Panel, about 800 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 468 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two
→Jackery SolarSaga 200 (JS-200D), about 400 W with two

All 33 panels checked against the Explorer 2000 Plus

Rules we applied
  • Jackery Explorer 2000 Plus: solar input 11 to 60 V on the Solar in 1 (DC8020). Jackery rates this input by working voltage (Vmp), so that is the number we hold to the limit. We still warn when the cold-morning open-circuit voltage goes over it.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 41.4 V becomes 45.3 V.
  • Current over the 8 A cap is safe: the station takes 8 A and you get fewer watts. We count only the capped watts.
  • Max 700 W on this input, 1,400 W across all inputs.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
Checked Oct 28, 2026