Will the Renogy 50W Mono N-Type Rigid Solar Panel work with the Goal Zero Yeti 200X?

No. Open-circuit voltage 22.3V is above the station's 22V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on 8mm), about 0 W.

Verdict

Don't connect

Do not plug this in. Open-circuit voltage 22.3V is above the station's 22V limit. Going over a station's input voltage limit can damage it.

1 x 50W Mono N-Type Rigid Solar Panel1 panel on 8mm
Yeti 200X8mm
Expected
0W
Voltage at 20F
24.4V
limit 22 V
Current
2.7A
cap 7 A
  • Open-circuit voltage 22.3V is above the station's 22V limit. Going over a station's input voltage limit can damage it.
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • Its AC outlet is modified sine wave, which some devices (and most CPAPs with humidifiers) do not like.
Cables to buyNone. Do not connect this combination. Pick a panel with lower open-circuit voltage, or fewer in series.
Renogy 50W Mono N-Type Rigid Solar Panel

50 W, open-circuit 22.3 V, short-circuit 2.9 A, working 18.6 V / 2.7 A. Brand page Panel details

Goal Zero Yeti 200X

Solar input 8mm: 13 to 22 V, 100 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on 8mm
Open-circuit voltage 22.3V is above the station's 22V limit. Going over a station's input voltage limit can damage it.
8mm24.45.40Don't connect
2 panels in series on 8mm
Open-circuit voltage 44.6V is above the station's 22V limit. Going over a station's input voltage limit can damage it.
8mm48.82.70Don't connect

Quick answers

Will the Renogy 50W Mono N-Type Rigid Solar Panel work with the Goal Zero Yeti 200X?

No. Open-circuit voltage 22.3V is above the station's 22V limit. Going over a station's input voltage limit can damage it. Two panels: don't connect (2 panels in parallel on 8mm), about 0 W.

Can I connect two 50W Mono N-Type Rigid Solar Panel panels to the Yeti 200X?

No: Open-circuit voltage 22.3V is above the station's 22V limit. Going over a station's input voltage limit can damage it.

Is it safe on a cold morning?

Panel voltage rises in the cold. One 50W Mono N-Type Rigid Solar Panel goes from 22.3 V on its label to about 24.4 V at 20°F and 25.2 V at 0°F. The Yeti 200X accepts up to 22 V on the 8mm.

Where to buy

$56 at the Renogy store, Oct 28, 2026
BuyAmazon
Out of stock at the Goal Zero store
View at store

We may earn a commission if you buy through these links. It never changes a verdict.

Rules we applied
  • Goal Zero Yeti 200X: solar input 13 to 22 V on the Solar in (8mm). Goal Zero does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 22.3 V becomes 24.4 V.
  • Current over the 7 A cap is safe: the station takes 7 A and you get fewer watts. We count only the capped watts.
  • Max 100 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
Checked Oct 28, 2026