We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the BLUETTI PV100 FX Flexible Solar Panel work with the Goal Zero Yeti 1500?

Yes. One BLUETTI PV100 FX Flexible Solar Panel works with the Goal Zero Yeti 1500: about 45.3 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on HPP), about 200 W.

Verdict

Works

1 x PV100 FX Flexible Solar Panel into the Yeti 1500 (1 panel on HPP) stays inside 12.3 to 60 V and under 20 A, even at 20F.

1 x PV100 FX Flexible Solar Panel1 panel on HPP
Yeti 1500HPP
Expected
100W
Voltage at 20F
45.3V
limit 60 V
Current
3.1A
cap 20 A
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • 41.4 V open circuit is high for a 100 W panel: two in series reach 82.8 V, more than most stations take.
  • The BLUETTI US store sells it only in sets of 2 or more.
Cables to buy
  • Needs an MC4 to HPP (Anderson Powerpole) adapter cable.
BLUETTI PV100 FX Flexible Solar Panel

100 W, open-circuit 41.4 V, short-circuit 3.1 A. Brand page Panel details

Goal Zero Yeti 1500

Solar input HPP: 12.3 to 60 V; 8mm: 13.2 to 30 V, 900 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on HPP
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
HPP45.36.1200Works
1 panel on HPP + 1 panel on 8mm
The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
HPP + 8mm45.33.10Don't connect
2 panels in series on HPP
Open-circuit voltage 82.8V is above the station's 60V limit. Going over a station's input voltage limit can damage it.
HPP90.73.10Don't connect
2 panels in parallel on 8mm
Open-circuit voltage 41.4V is above the station's 30V limit. Going over a station's input voltage limit can damage it.
8mm45.36.10Don't connect
2 panels in series on 8mm
Open-circuit voltage 82.8V is above the station's 30V limit. Going over a station's input voltage limit can damage it.
8mm90.73.10Don't connect

Quick answers

Will the BLUETTI PV100 FX Flexible Solar Panel work with the Goal Zero Yeti 1500?

Yes. One BLUETTI PV100 FX Flexible Solar Panel works with the Goal Zero Yeti 1500: about 45.3 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on HPP), about 200 W.

Can I connect two PV100 FX Flexible Solar Panel panels to the Yeti 1500?

Yes, 2 panels in parallel on HPP. That gives about 200 W.

What cable do I need to connect the PV100 FX Flexible Solar Panel to the Yeti 1500?

Needs an MC4 to HPP (Anderson Powerpole) adapter cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PV100 FX Flexible Solar Panel goes from 41.4 V on its label to about 45.3 V at 20°F and 46.7 V at 0°F. The Yeti 1500 accepts up to 60 V on the HPP.

Where to buy

$1,500 at the Goal Zero store, Oct 28, 2026
Buy

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the Yeti 1500

→EcoFlow 400W Portable Solar Panel, about 600 W with two
→BLUETTI PV350D, about 552 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two

All 33 panels checked against the Yeti 1500

Rules we applied
  • Goal Zero Yeti 1500: solar input 12.3 to 60 V on the Solar in 1 (HPP). Goal Zero does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 41.4 V becomes 45.3 V.
  • Current over the 20 A cap is safe: the station takes 20 A and you get fewer watts. We count only the capped watts.
  • Max 600 W on this input, 900 W across all inputs.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
Checked Oct 28, 2026