Will the BLUETTI PV120 Solar Panel work with the EcoFlow RIVER?
Yes, with a catch. Fine in mild weather (24.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.7V, above the 25V limit. Cold makes panels push more voltage. Two panels: works, with a catch (2 panels in parallel on Solar input), about 200 W.
Works, with a catch
It charges, but read the note. Best option: 1 panel on Solar input.
- Fine in mild weather (24.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.7V, above the 25V limit. Cold makes panels push more voltage.
- Use the solar charging cable that came with the station (MC4 on the panel side).
120 W, open-circuit 24.4 V, short-circuit 6.4 A, working 19.6 V / 6.1 A. Brand page Panel details
EcoFlow RIVERSolar input Solar input: 10 to 25 V, 200 W max. Brand page Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in parallel on Solar input Fine in mild weather (24.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.7V, above the 25V limit. Cold makes panels push more voltage. | Solar input | 26.7 | 12.2 | 200 | Works, with a catch |
| 2 panels in series on Solar input Open-circuit voltage 48.8V is above the station's 25V limit. Going over a station's input voltage limit can damage it. | Solar input | 53.4 | 6.1 | 0 | Don't connect |
Quick answers
Will the BLUETTI PV120 Solar Panel work with the EcoFlow RIVER?
Yes, with a catch. Fine in mild weather (24.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.7V, above the 25V limit. Cold makes panels push more voltage. Two panels: works, with a catch (2 panels in parallel on Solar input), about 200 W.
Can I connect two PV120 Solar Panel panels to the RIVER?
Yes, 2 panels in parallel on Solar input. That gives about 200 W, with one catch: Fine in mild weather (24.4V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 26.7V, above the 25V limit. Cold makes panels push more voltage..
What cable do I need to connect the PV120 Solar Panel to the RIVER?
Use the solar charging cable that came with the station (MC4 on the panel side).
Is it safe on a cold morning?
Panel voltage rises in the cold. One PV120 Solar Panel goes from 24.4 V on its label to about 26.7 V at 20°F and 27.5 V at 0°F. The RIVER accepts up to 25 V on the Solar input.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the RIVER
- EcoFlow RIVER: solar input 10 to 25 V on the Solar in (Solar input). EcoFlow sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 24.4 V becomes 26.7 V.
- Current over the 12 A cap is safe: the station takes 12 A and you get fewer watts. We count only the capped watts.
- Max 200 W on this input.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.