We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the EcoFlow 100W Rigid Solar Panel work with the EcoFlow DELTA mini?

Yes. One EcoFlow 100W Rigid Solar Panel works with the EcoFlow DELTA mini: about 22.4 V on a 20°F morning against the station's 75 V limit, and about 100 W in full sun. Two panels: works (2 panels in series on Solar input), about 200 W.

Verdict

Works

1 x 100W Rigid Solar Panel into the DELTA mini (1 panel on Solar input) stays inside 11 to 75 V and under 10 A, even at 20F.

1 x 100W Rigid Solar Panel1 panel on Solar input
DELTA miniSolar input
Expected
100W
Voltage at 20F
22.4V
limit 75 V
Current
5.9A
cap 10 A
Cables to buy
  • Use the solar charging cable that came with the station (MC4 on the panel side).
EcoFlow 100W Rigid Solar Panel

100 W, open-circuit 20.3 V, short-circuit 6.3 A, working 17.1 V / 5.9 A. Brand page Panel details

EcoFlow DELTA mini

Solar input Solar input: 11 to 75 V, 300 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in series on Solar input
Best option
Solar input44.85.9200Works
2 panels in parallel on Solar input
The panels can push 11.8A but this input takes 10A, so the station caps it. Safe, you just lose some watts.
Solar input22.411.8171Works

Quick answers

Will the EcoFlow 100W Rigid Solar Panel work with the EcoFlow DELTA mini?

Yes. One EcoFlow 100W Rigid Solar Panel works with the EcoFlow DELTA mini: about 22.4 V on a 20°F morning against the station's 75 V limit, and about 100 W in full sun. Two panels: works (2 panels in series on Solar input), about 200 W.

Can I connect two 100W Rigid Solar Panel panels to the DELTA mini?

Yes, 2 panels in series on Solar input. That gives about 200 W.

What cable do I need to connect the 100W Rigid Solar Panel to the DELTA mini?

Use the solar charging cable that came with the station (MC4 on the panel side).

Is it safe on a cold morning?

Panel voltage rises in the cold. One 100W Rigid Solar Panel goes from 20.3 V on its label to about 22.4 V at 20°F and 23.2 V at 0°F. The DELTA mini accepts up to 75 V on the Solar input.

Where to buy

Out of stock at the EcoFlow store
View at store
Out of stock at the EcoFlow store
View at store

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the DELTA mini

→Jackery SolarSaga 200 (JS-200E), about 300 W with two
→Jackery SolarSaga 200 (JS-200D), about 300 W with two
→EcoFlow 400W Portable Solar Panel, about 300 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 300 W with two
→BLUETTI PV200D, about 300 W with two

All 33 panels checked against the DELTA mini

Rules we applied
  • EcoFlow DELTA mini: solar input 11 to 75 V on the Solar in (Solar input). EcoFlow sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
  • Cold raises panel voltage: we add 0.33% per °C below 77F (25°C), this panel's own figure. At 20F one panel's 20.3 V becomes 22.4 V.
  • Current over the 10 A cap is safe: the station takes 10 A and you get fewer watts. We count only the capped watts.
  • Max 300 W on this input.
Assumptions
  • Cold-morning voltage uses this panel's own coefficient from its manual, 0.33% per °C.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
Checked Oct 28, 2026