Will the EcoFlow 100W Rigid Solar Panel work with the EcoFlow DELTA 3 Ultra?
Yes. One EcoFlow 100W Rigid Solar Panel works with the EcoFlow DELTA 3 Ultra: about 22.4 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on Solar input (XT60i)), about 200 W.
Works
1 x 100W Rigid Solar Panel into the DELTA 3 Ultra (1 panel on Solar input (XT60i)) stays inside 11 to 60 V and under 18 A, even at 20F.
- Use an MC4 to XT60i solar cable.
100 W, open-circuit 20.3 V, short-circuit 6.3 A, working 17.1 V / 5.9 A. Brand page Panel details
EcoFlow DELTA 3 UltraSolar input Solar input (XT60i): 11 to 60 V, 800 W max. Manual Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 2 panels in parallel on Solar input (XT60i) Best option | Solar input (XT60i) | 22.4 | 11.8 | 200 | Works |
| 2 panels in series on Solar input (XT60i) | Solar input (XT60i) | 44.8 | 5.9 | 200 | Works |
Quick answers
Will the EcoFlow 100W Rigid Solar Panel work with the EcoFlow DELTA 3 Ultra?
Yes. One EcoFlow 100W Rigid Solar Panel works with the EcoFlow DELTA 3 Ultra: about 22.4 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on Solar input (XT60i)), about 200 W.
Can I connect two 100W Rigid Solar Panel panels to the DELTA 3 Ultra?
Yes, 2 panels in parallel on Solar input (XT60i). That gives about 200 W.
What cable do I need to connect the 100W Rigid Solar Panel to the DELTA 3 Ultra?
Use an MC4 to XT60i solar cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One 100W Rigid Solar Panel goes from 20.3 V on its label to about 22.4 V at 20°F and 23.2 V at 0°F. The DELTA 3 Ultra accepts up to 60 V on the Solar input (XT60i).
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the DELTA 3 Ultra
- EcoFlow DELTA 3 Ultra: solar input 11 to 60 V on the Solar in (Solar input (XT60i)). EcoFlow sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
- Cold raises panel voltage: we add 0.33% per °C below 77F (25°C), this panel's own figure. At 20F one panel's 20.3 V becomes 22.4 V.
- Current over the 18 A cap is safe: the station takes 18 A and you get fewer watts. We count only the capped watts.
- Max 800 W on this input.
- Cold-morning voltage uses this panel's own coefficient from its manual, 0.33% per °C.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.