We may earn a commission if you buy through these links. It never changes a verdict. How this works

Will the Rich Solar MEGA 50 work with the EcoFlow DELTA 3 Plus?

Yes. One Rich Solar MEGA 50 works with the EcoFlow DELTA 3 Plus: about 22.8 V on a 20°F morning against the station's 60 V limit, and about 50 W in full sun. Two panels: works (1 panel on XT60i + 1 panel on XT60i), about 100 W.

Verdict

Works

1 x MEGA 50 into the DELTA 3 Plus (1 panel on XT60i) stays inside 11 to 60 V and under 15 A, even at 20F.

1 x MEGA 501 panel on XT60i
DELTA 3 PlusXT60i
Expected
50W
Voltage at 20F
22.8V
limit 60 V
Current
3.1A
cap 15 A
  • EcoFlow's manual: keep the total open-circuit voltage within 60V and the total short-circuit current within 15A on each input, or the station can be damaged.
  • Short-circuit current is printed on the panel label as Isc. It is a little higher than the working current, so two panels in parallel usually go over 15A.
  • If the solar icon on the screen flashes, the light is too weak or the voltage is too high or too low.
  • When solar and wall power are both plugged in, the station uses solar first.
Cables to buy
  • Use an MC4 to XT60i solar cable.
Rich Solar MEGA 50

50 W, open-circuit 20.8 V, short-circuit 3.1 A, working 17.6 V / 2.8 A. Brand page Panel details

EcoFlow DELTA 3 Plus

Solar input XT60i: 11 to 60 V; XT60i: 11 to 60 V, 1000 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
1 panel on XT60i + 1 panel on XT60i
Best option
XT60i + XT60i22.83.1100Works
2 panels in parallel on XT60i
XT60i22.86.3100Works
2 panels in series on XT60i
XT60i45.63.1100Works

Quick answers

Will the Rich Solar MEGA 50 work with the EcoFlow DELTA 3 Plus?

Yes. One Rich Solar MEGA 50 works with the EcoFlow DELTA 3 Plus: about 22.8 V on a 20°F morning against the station's 60 V limit, and about 50 W in full sun. Two panels: works (1 panel on XT60i + 1 panel on XT60i), about 100 W.

Can I connect two MEGA 50 panels to the DELTA 3 Plus?

Yes, 1 panel on XT60i + 1 panel on XT60i. That gives about 100 W.

What cable do I need to connect the MEGA 50 to the DELTA 3 Plus?

Use an MC4 to XT60i solar cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One MEGA 50 goes from 20.8 V on its label to about 22.8 V at 20°F and 23.5 V at 0°F. The DELTA 3 Plus accepts up to 60 V on the XT60i.

Where to buy

$70 at the Rich Solar store, Oct 28, 2026
Buy
$719 at the EcoFlow store, Oct 28, 2026
BuyAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the DELTA 3 Plus

→EcoFlow 400W Portable Solar Panel, about 800 W with two
→BLUETTI PV350D, about 700 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two

All 33 panels checked against the DELTA 3 Plus

Rules we applied
  • EcoFlow DELTA 3 Plus: solar input 11 to 60 V on the Solar in 1 (XT60i). EcoFlow sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 20.8 V becomes 22.8 V.
  • EcoFlow says to keep the total short-circuit current (Isc) within 15 A on each input. Over it, we say Don't connect.
  • Max 500 W on this input, 1,000 W across all inputs.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
From the brand's pageMEGA 50 label values
Checked Oct 28, 2026