We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the EcoFlow 175W Rigid Solar Panel work with the EcoFlow DELTA 3 Plus?

Yes. One EcoFlow 175W Rigid Solar Panel works with the EcoFlow DELTA 3 Plus: about 27.9 V on a 20°F morning against the station's 60 V limit, and about 175 W in full sun. Two panels: works (1 panel on XT60i + 1 panel on XT60i), about 350 W.

Verdict

Works

1 x 175W Rigid Solar Panel into the DELTA 3 Plus (1 panel on XT60i) stays inside 11 to 60 V and under 15 A, even at 20F.

1 x 175W Rigid Solar Panel1 panel on XT60i
DELTA 3 PlusXT60i
Expected
175W
Voltage at 20F
27.9V
limit 60 V
Current
8.3A
cap 15 A
  • EcoFlow's manual: keep the total open-circuit voltage within 60V and the total short-circuit current within 15A on each input, or the station can be damaged.
  • Short-circuit current is printed on the panel label as Isc. It is a little higher than the working current, so two panels in parallel usually go over 15A.
  • If the solar icon on the screen flashes, the light is too weak or the voltage is too high or too low.
  • When solar and wall power are both plugged in, the station uses solar first.
  • EcoFlow's spec table labels the 7.85 A figure as a voltage; it is the operating current.
Cables to buy
  • Use an MC4 to XT60i solar cable.
EcoFlow 175W Rigid Solar Panel

175 W, open-circuit 25.5 V, short-circuit 8.3 A, working 22.3 V / 7.9 A. Brand page Panel details

EcoFlow DELTA 3 Plus

Solar input XT60i: 11 to 60 V; XT60i: 11 to 60 V, 1000 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
1 panel on XT60i + 1 panel on XT60i
Best option
XT60i + XT60i27.98.3350Works
2 panels in series on XT60i
XT60i55.88.3350Works
2 panels in parallel on XT60i
Total short-circuit current 16.6A is above the 15A the manual allows for this input. The manual says to stay within it to avoid damage.
XT60i27.916.60Don't connect

Quick answers

Will the EcoFlow 175W Rigid Solar Panel work with the EcoFlow DELTA 3 Plus?

Yes. One EcoFlow 175W Rigid Solar Panel works with the EcoFlow DELTA 3 Plus: about 27.9 V on a 20°F morning against the station's 60 V limit, and about 175 W in full sun. Two panels: works (1 panel on XT60i + 1 panel on XT60i), about 350 W.

Can I connect two 175W Rigid Solar Panel panels to the DELTA 3 Plus?

Yes, 1 panel on XT60i + 1 panel on XT60i. That gives about 350 W.

What cable do I need to connect the 175W Rigid Solar Panel to the DELTA 3 Plus?

Use an MC4 to XT60i solar cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One 175W Rigid Solar Panel goes from 25.5 V on its label to about 27.9 V at 20°F and 28.8 V at 0°F. The DELTA 3 Plus accepts up to 60 V on the XT60i.

Where to buy

$249 at the EcoFlow store, Oct 28, 2026
BuyAmazon
$719 at the EcoFlow store, Oct 28, 2026
BuyAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the DELTA 3 Plus

→EcoFlow 400W Portable Solar Panel, about 800 W with two
→BLUETTI PV350D, about 700 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two

All 33 panels checked against the DELTA 3 Plus

Rules we applied
  • EcoFlow DELTA 3 Plus: solar input 11 to 60 V on the Solar in 1 (XT60i). EcoFlow sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 25.5 V becomes 27.9 V.
  • EcoFlow says to keep the total short-circuit current (Isc) within 15 A on each input. Over it, we say Don't connect.
  • Max 500 W on this input, 1,000 W across all inputs.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
Checked Oct 28, 2026