Will the Anker SOLIX PS400 Bifacial work with the EcoFlow DELTA 3 Plus?
Yes, with a catch. Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage. Two panels: works, with a catch (1 panel on XT60i + 1 panel on XT60i), about 800 W.
Works, with a catch
It charges, but read the note. Best option: 1 panel on XT60i.
- Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage.
- EcoFlow's manual: keep the total open-circuit voltage within 60V and the total short-circuit current within 15A on each input, or the station can be damaged.
- Short-circuit current is printed on the panel label as Isc. It is a little higher than the working current, so two panels in parallel usually go over 15A.
- If the solar icon on the screen flashes, the light is too weak or the voltage is too high or too low.
- When solar and wall power are both plugged in, the station uses solar first.
- 57.6 V open circuit: above the 55-60 V limit of many smaller stations even as a single panel on a cold morning.
- Use an MC4 to XT60i solar cable.
400 W, open-circuit 57.6 V, short-circuit 8.8 A, working 48 V / 8.3 A. Unconfirmed Panel details
EcoFlow DELTA 3 PlusSolar input XT60i: 11 to 60 V; XT60i: 11 to 60 V, 1000 W max. Manual Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 1 panel on XT60i + 1 panel on XT60i Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage. | XT60i + XT60i | 63.1 | 8.8 | 800 | Works, with a catch |
| 2 panels in parallel on XT60i Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage. | XT60i | 63.1 | 17.5 | 0 | Don't connect |
| 2 panels in series on XT60i Open-circuit voltage 115.2V is above the station's 60V limit. Going over a station's input voltage limit can damage it. | XT60i | 126.1 | 8.8 | 0 | Don't connect |
Quick answers
Will the Anker SOLIX PS400 Bifacial work with the EcoFlow DELTA 3 Plus?
Yes, with a catch. Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage. Two panels: works, with a catch (1 panel on XT60i + 1 panel on XT60i), about 800 W.
Can I connect two PS400 Bifacial panels to the DELTA 3 Plus?
Yes, 1 panel on XT60i + 1 panel on XT60i. That gives about 800 W, with one catch: Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage..
What cable do I need to connect the PS400 Bifacial to the DELTA 3 Plus?
Use an MC4 to XT60i solar cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One PS400 Bifacial goes from 57.6 V on its label to about 63.1 V at 20°F and 65 V at 0°F. The DELTA 3 Plus accepts up to 60 V on the XT60i.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the DELTA 3 Plus
- EcoFlow DELTA 3 Plus: solar input 11 to 60 V on the Solar in 1 (XT60i). EcoFlow sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 57.6 V becomes 63.1 V.
- EcoFlow says to keep the total short-circuit current (Isc) within 15 A on each input. Over it, we say Don't connect.
- Max 500 W on this input, 1,000 W across all inputs.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
- Some numbers for Anker SOLIX PS400 Bifacial come from a shop listing we have not confirmed in the manual yet.