We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the BLUETTI PV100 FX Flexible Solar Panel work with the EcoFlow DELTA 3 Max?

Yes. One BLUETTI PV100 FX Flexible Solar Panel works with the EcoFlow DELTA 3 Max: about 45.3 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on Solar/Car input (XT60i)), about 200 W.

Verdict

Works

1 x PV100 FX Flexible Solar Panel into the DELTA 3 Max (1 panel on Solar/Car input (XT60i)) stays inside 11 to 60 V and under 13 A, even at 20F.

1 x PV100 FX Flexible Solar Panel1 panel on Solar/Car input (XT60i)
DELTA 3 MaxSolar/Car input (XT60i)
Expected
100W
Voltage at 20F
45.3V
limit 60 V
Current
3.1A
cap 13 A
  • 41.4 V open circuit is high for a 100 W panel: two in series reach 82.8 V, more than most stations take.
  • The BLUETTI US store sells it only in sets of 2 or more.
Cables to buy
  • Use an MC4 to XT60i solar cable.
BLUETTI PV100 FX Flexible Solar Panel

100 W, open-circuit 41.4 V, short-circuit 3.1 A. Brand page Panel details

EcoFlow DELTA 3 Max

Solar input Solar/Car input (XT60i): 11 to 60 V, 500 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on Solar/Car input (XT60i)
Best option
Solar/Car input (XT60i)45.36.1200Works
2 panels in series on Solar/Car input (XT60i)
Open-circuit voltage 82.8V is above the station's 60V limit. Going over a station's input voltage limit can damage it.
Solar/Car input (XT60i)90.73.10Don't connect

Quick answers

Will the BLUETTI PV100 FX Flexible Solar Panel work with the EcoFlow DELTA 3 Max?

Yes. One BLUETTI PV100 FX Flexible Solar Panel works with the EcoFlow DELTA 3 Max: about 45.3 V on a 20°F morning against the station's 60 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on Solar/Car input (XT60i)), about 200 W.

Can I connect two PV100 FX Flexible Solar Panel panels to the DELTA 3 Max?

Yes, 2 panels in parallel on Solar/Car input (XT60i). That gives about 200 W.

What cable do I need to connect the PV100 FX Flexible Solar Panel to the DELTA 3 Max?

Use an MC4 to XT60i solar cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One PV100 FX Flexible Solar Panel goes from 41.4 V on its label to about 45.3 V at 20°F and 46.7 V at 0°F. The DELTA 3 Max accepts up to 60 V on the Solar/Car input (XT60i).

Where to buy

$899 at the EcoFlow store, Oct 28, 2026
BuyAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the DELTA 3 Max

→EcoFlow 400W Portable Solar Panel, about 500 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two
→Jackery SolarSaga 200 (JS-200D), about 400 W with two

All 33 panels checked against the DELTA 3 Max

Rules we applied
  • EcoFlow DELTA 3 Max: solar input 11 to 60 V on the Solar in (Solar/Car input (XT60i)). EcoFlow sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 41.4 V becomes 45.3 V.
  • Current over the 13 A cap is safe: the station takes 13 A and you get fewer watts. We count only the capped watts.
  • Max 500 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
Checked Oct 28, 2026