We may earn a commission if you buy through these links. It never changes a verdict. How this works
Find my setup

Will the Renogy 200W N-Type Solar Panel work with the EcoFlow DELTA 3 Max Plus?

Yes. One Renogy 200W N-Type Solar Panel works with the EcoFlow DELTA 3 Max Plus: about 25.2 V on a 20°F morning against the station's 60 V limit, and about 200 W in full sun. Two panels: works (1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)), about 400 W.

Verdict

Works

1 x 200W N-Type Solar Panel into the DELTA 3 Max Plus (1 panel on Solar/Car input 1 (XT60i)) stays inside 11 to 60 V and under 18 A, even at 20F.

1 x 200W N-Type Solar Panel1 panel on Solar/Car input 1 (XT60i)
DELTA 3 Max PlusSolar/Car input 1 (XT60i)
Expected
200W
Voltage at 20F
25.2V
limit 60 V
Current
10.4A
cap 18 A
Cables to buy
  • Use an MC4 to XT60i solar cable.
Renogy 200W N-Type Solar Panel

200 W, open-circuit 23 V, short-circuit 11.1 A, working 19.2 V / 10.4 A. Brand page Panel details

EcoFlow DELTA 3 Max Plus

Solar input Solar/Car input 1 (XT60i): 11 to 60 V; Solar/Car input 2 (XT60i): 11 to 60 V, 1000 W max. Manual Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)
Best option
Solar/Car input 1 (XT60i) + Solar/Car input 2 (XT60i)25.210.4400Works
2 panels in series on Solar/Car input 1 (XT60i)
Solar/Car input 1 (XT60i)50.410.4400Works
2 panels in series on Solar/Car input 2 (XT60i)
Solar/Car input 2 (XT60i)50.410.4400Works
2 panels in parallel on Solar/Car input 1 (XT60i)
The panels can push 20.8A but this input takes 18A, so the station caps it. Safe, you just lose some watts.
Solar/Car input 1 (XT60i)25.220.8346Works
2 panels in parallel on Solar/Car input 2 (XT60i)
The panels can push 20.8A but this input takes 18A, so the station caps it. Safe, you just lose some watts.
Solar/Car input 2 (XT60i)25.220.8346Works

Quick answers

Will the Renogy 200W N-Type Solar Panel work with the EcoFlow DELTA 3 Max Plus?

Yes. One Renogy 200W N-Type Solar Panel works with the EcoFlow DELTA 3 Max Plus: about 25.2 V on a 20°F morning against the station's 60 V limit, and about 200 W in full sun. Two panels: works (1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i)), about 400 W.

Can I connect two 200W N-Type Solar Panel panels to the DELTA 3 Max Plus?

Yes, 1 panel on Solar/Car input 1 (XT60i) + 1 panel on Solar/Car input 2 (XT60i). That gives about 400 W.

What cable do I need to connect the 200W N-Type Solar Panel to the DELTA 3 Max Plus?

Use an MC4 to XT60i solar cable.

Is it safe on a cold morning?

Panel voltage rises in the cold. One 200W N-Type Solar Panel goes from 23 V on its label to about 25.2 V at 20°F and 26 V at 0°F. The DELTA 3 Max Plus accepts up to 60 V on the Solar/Car input 1 (XT60i).

Where to buy

$180 at the Renogy store, Oct 28, 2026
Buy
$1,199 at the EcoFlow store, Oct 28, 2026
BuyAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the DELTA 3 Max Plus

→EcoFlow 400W Portable Solar Panel, about 800 W with two
→BLUETTI PV350D, about 700 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two

All 33 panels checked against the DELTA 3 Max Plus

Rules we applied
  • EcoFlow DELTA 3 Max Plus: solar input 11 to 60 V on the Solar in 1 (Solar/Car input 1 (XT60i)). EcoFlow sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 23 V becomes 25.2 V.
  • Current over the 18 A cap is safe: the station takes 18 A and you get fewer watts. We count only the capped watts.
  • Max 500 W on this input, 1,000 W across all inputs.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
Checked Oct 28, 2026