Will the BLUETTI PV200D work with the EcoFlow DELTA 2 Max?
Yes. One BLUETTI PV200D works with the EcoFlow DELTA 2 Max: about 26.9 V on a 20°F morning against the station's 60 V limit, and about 198 W in full sun. Two panels: works (1 panel on Solar input + 1 panel on Solar input), about 396 W.
Works
1 x PV200D into the DELTA 2 Max (1 panel on Solar input) stays inside 11 to 60 V and under 15 A, even at 20F.
- The panel's plug type is not confirmed yet. Check the label or the box before buying a cable.
200 W, open-circuit 24.6 V, short-circuit 10.8 A, working 20.4 V / 9.7 A. Manual Panel details
EcoFlow DELTA 2 MaxSolar input Solar input: 11 to 60 V; Solar input: 11 to 60 V, 1000 W max. Brand page Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 1 panel on Solar input + 1 panel on Solar input Best option | Solar input + Solar input | 26.9 | 9.7 | 396 | Works |
| 2 panels in series on Solar input | Solar input | 53.9 | 9.7 | 396 | Works |
| 2 panels in parallel on Solar input The panels can push 19.4A but this input takes 15A, so the station caps it. Safe, you just lose some watts. | Solar input | 26.9 | 19.4 | 306 | Works |
Quick answers
Will the BLUETTI PV200D work with the EcoFlow DELTA 2 Max?
Yes. One BLUETTI PV200D works with the EcoFlow DELTA 2 Max: about 26.9 V on a 20°F morning against the station's 60 V limit, and about 198 W in full sun. Two panels: works (1 panel on Solar input + 1 panel on Solar input), about 396 W.
Can I connect two PV200D panels to the DELTA 2 Max?
Yes, 1 panel on Solar input + 1 panel on Solar input. That gives about 396 W.
What cable do I need to connect the PV200D to the DELTA 2 Max?
The panel's plug type is not confirmed yet. Check the label or the box before buying a cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One PV200D goes from 24.6 V on its label to about 26.9 V at 20°F and 27.8 V at 0°F. The DELTA 2 Max accepts up to 60 V on the Solar input.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the DELTA 2 Max
- EcoFlow DELTA 2 Max: solar input 11 to 60 V on the Solar in 1 (Solar input). EcoFlow sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 24.6 V becomes 26.9 V.
- Current over the 15 A cap is safe: the station takes 15 A and you get fewer watts. We count only the capped watts.
- Max 500 W on this input, 1,000 W across all inputs.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.