We may earn a commission if you buy through these links. It never changes a verdict. How this works

Will the Rich Solar MEGA 100 FLEX work with the BLUETTI Elite 10 Mini?

Yes. One Rich Solar MEGA 100 FLEX works with the BLUETTI Elite 10 Mini: about 22.3 V on a 20°F morning against the station's 28 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on Solar input), about 100 W.

Verdict

Works

1 x MEGA 100 FLEX into the Elite 10 Mini (1 panel on Solar input) stays inside 12 to 28 V and under 8.2 A, even at 20F.

1 x MEGA 100 FLEX1 panel on Solar input
Elite 10 MiniSolar input
Expected
100W
Voltage at 20F
22.3V
limit 28 V
Current
5.9A
cap 8.2 A
Cables to buy
  • Use the solar charging cable that came with the station (MC4 on the panel side).
Rich Solar MEGA 100 FLEX

100 W, open-circuit 20.4 V, short-circuit 6.1 A, working 17.1 V / 5.9 A. Brand page Panel details

BLUETTI Elite 10 Mini

Solar input Solar input: 12 to 28 V, 100 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on Solar input
The panels can push 11.7A but this input takes 8.2A, so the station caps it. Safe, you just lose some watts.
Solar input22.311.7100Works
2 panels in series on Solar input
Open-circuit voltage 40.8V is above the station's 28V limit. Going over a station's input voltage limit can damage it.
Solar input44.75.90Don't connect

Quick answers

Will the Rich Solar MEGA 100 FLEX work with the BLUETTI Elite 10 Mini?

Yes. One Rich Solar MEGA 100 FLEX works with the BLUETTI Elite 10 Mini: about 22.3 V on a 20°F morning against the station's 28 V limit, and about 100 W in full sun. Two panels: works (2 panels in parallel on Solar input), about 100 W.

Can I connect two MEGA 100 FLEX panels to the Elite 10 Mini?

Yes, 2 panels in parallel on Solar input. That gives about 100 W.

What cable do I need to connect the MEGA 100 FLEX to the Elite 10 Mini?

Use the solar charging cable that came with the station (MC4 on the panel side).

Is it safe on a cold morning?

Panel voltage rises in the cold. One MEGA 100 FLEX goes from 20.4 V on its label to about 22.3 V at 20°F and 23 V at 0°F. The Elite 10 Mini accepts up to 28 V on the Solar input.

Where to buy

$170 at the Rich Solar store, Oct 28, 2026
Buy
$119 at the BLUETTI store, Oct 28, 2026
BuyAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the Elite 10 Mini

→Jackery SolarSaga 200 (JS-200E), about 100 W with two
→Jackery SolarSaga 200 (JS-200D), about 100 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 100 W with two
→BLUETTI PV200D, about 100 W with two
→EcoFlow 100W Rigid Solar Panel, about 100 W with two

All 33 panels checked against the Elite 10 Mini

Rules we applied
  • BLUETTI Elite 10 Mini: solar input 12 to 28 V on the Solar in (Solar input). BLUETTI sets this limit on open-circuit voltage (Voc), so we hold the panels' Voc on your coldest morning to it.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 20.4 V becomes 22.3 V.
  • Current over the 8.2 A cap is safe: the station takes 8.2 A and you get fewer watts. We count only the capped watts.
  • Max 100 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
Sources
From the brand's pageMEGA 100 FLEX label values
Checked Oct 28, 2026