Will the BLUETTI PV350D work with the Anker SOLIX F3800 Plus?
Yes. One BLUETTI PV350D works with the Anker SOLIX F3800 Plus: about 36.1 V on a 20°F morning against the station's 165 V limit, and about 350 W in full sun. Two panels: works (1 panel on Solar input + 1 panel on Solar input), about 700 W.
Works
1 x PV350D into the F3800 Plus (1 panel on Solar input) stays inside 11 to 165 V and under 17 A, even at 20F.
- The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
- Anker does not say whether its voltage limit is open-circuit or working voltage, so the checker uses the stricter reading.
- Anker's page: going over 165V can damage the solar input ports.
- The panel's plug type is not confirmed yet. Check the label or the box before buying a cable.
350 W, open-circuit 33 V, short-circuit 13.8 A, working 27.6 V / 12.7 A. Manual Panel details
Anker SOLIX F3800 PlusSolar input Solar input: 11 to 165 V; Solar input: 11 to 165 V, 3200 W max. Brand page Station details
Change the count or temperatureTwo panels: every way to wire them
| Wiring | Input | Volts at 20F | Amps | Watts | Verdict |
|---|---|---|---|---|---|
| 1 panel on Solar input + 1 panel on Solar input The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | Solar input + Solar input | 36.1 | 12.7 | 700 | Works |
| 2 panels in series on Solar input The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | Solar input | 72.3 | 12.7 | 700 | Works |
| 2 panels in parallel on Solar input The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number. | Solar input | 36.1 | 25.4 | 469 | Works |
Quick answers
Will the BLUETTI PV350D work with the Anker SOLIX F3800 Plus?
Yes. One BLUETTI PV350D works with the Anker SOLIX F3800 Plus: about 36.1 V on a 20°F morning against the station's 165 V limit, and about 350 W in full sun. Two panels: works (1 panel on Solar input + 1 panel on Solar input), about 700 W.
Can I connect two PV350D panels to the F3800 Plus?
Yes, 1 panel on Solar input + 1 panel on Solar input. That gives about 700 W.
What cable do I need to connect the PV350D to the F3800 Plus?
The panel's plug type is not confirmed yet. Check the label or the box before buying a cable.
Is it safe on a cold morning?
Panel voltage rises in the cold. One PV350D goes from 33 V on its label to about 36.1 V at 20°F and 37.2 V at 0°F. The F3800 Plus accepts up to 165 V on the Solar input.
Where to buy
We may earn a commission if you buy through these links. It never changes a verdict.
Other panels that work with the F3800 Plus
- Anker SOLIX F3800 Plus: solar input 11 to 165 V on the Solar in 1 (Solar input). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
- Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 33 V becomes 36.1 V.
- Current over the 17 A cap is safe: the station takes 17 A and you get fewer watts. We count only the capped watts.
- Max 1,600 W on this input, 3,200 W across all inputs.
- Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
- Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.