We may earn a commission if you buy through these links. It never changes a verdict. How this works

Will the Anker SOLIX PS400 Bifacial work with the Anker SOLIX F2600?

Yes, with a catch. Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage. Two panels: works, with a catch (2 panels in parallel on Solar input), about 800 W.

Verdict

Works, with a catch

It charges, but read the note. Best option: 1 panel on Solar input.

1 x PS400 Bifacial1 panel on Solar input
F2600Solar input
Expected
400W
Voltage at 20F
63.1V
limit 60 V
Current
8.3A
cap 20 A
  • Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage.
  • The brand does not say whether its voltage limit is open-circuit or working voltage, so we check against the stricter open-circuit number.
  • Anker does not say whether its voltage limit is open-circuit or working voltage, so the checker uses the stricter reading.
  • 57.6 V open circuit: above the 55-60 V limit of many smaller stations even as a single panel on a cold morning.
Cables to buy
  • Use the solar charging cable that came with the station (MC4 on the panel side).
Anker SOLIX PS400 Bifacial

400 W, open-circuit 57.6 V, short-circuit 8.8 A, working 48 V / 8.3 A. Unconfirmed Panel details

Anker SOLIX F2600

Solar input Solar input: 11 to 60 V, 1000 W max. Brand page Station details

Change the count or temperature

Two panels: every way to wire them

WiringInputVolts at 20FAmpsWattsVerdict
2 panels in parallel on Solar input
Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage.
Solar input63.116.7800Works, with a catch
2 panels in series on Solar input
Open-circuit voltage 115.2V is above the station's 60V limit. Going over a station's input voltage limit can damage it.
Solar input126.18.30Don't connect

Quick answers

Will the Anker SOLIX PS400 Bifacial work with the Anker SOLIX F2600?

Yes, with a catch. Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage. Two panels: works, with a catch (2 panels in parallel on Solar input), about 800 W.

Can I connect two PS400 Bifacial panels to the F2600?

Yes, 2 panels in parallel on Solar input. That gives about 800 W, with one catch: Fine in mild weather (57.6V), but on a 20°F (-7°C) morning the open-circuit voltage rises to about 63.1V, above the 60V limit. Cold makes panels push more voltage..

What cable do I need to connect the PS400 Bifacial to the F2600?

Use the solar charging cable that came with the station (MC4 on the panel side).

Is it safe on a cold morning?

Panel voltage rises in the cold. One PS400 Bifacial goes from 57.6 V on its label to about 63.1 V at 20°F and 65 V at 0°F. The F2600 accepts up to 60 V on the Solar input.

Where to buy

$700 at the Anker SOLIX store, Oct 28, 2026
BuyAmazon
Out of stock at the Anker SOLIX store
View at storeAmazon

We may earn a commission if you buy through these links. It never changes a verdict.

Other panels that work with the F2600

→EcoFlow 400W Portable Solar Panel, about 800 W with two
→BLUETTI PV350D, about 700 W with two
→Renogy 250W N-Type Bifacial Solar Panel, about 500 W with two
→EcoFlow NextGen 220W Bifacial Portable Solar Panel, about 438 W with two
→Jackery SolarSaga 200 (JS-200E), about 400 W with two

All 33 panels checked against the F2600

Rules we applied
  • Anker SOLIX F2600: solar input 11 to 60 V on the Solar in (Solar input). Anker SOLIX does not say whether this limit is open-circuit or working voltage, so we use the stricter reading: open-circuit voltage on your coldest morning.
  • Cold raises panel voltage: we add 0.30% per °C below 77F (25°C), a typical figure, since this panel does not publish its own. At 20F one panel's 57.6 V becomes 63.1 V.
  • Current over the 20 A cap is safe: the station takes 20 A and you get fewer watts. We count only the capped watts.
  • Max 1,000 W on this input.
Assumptions
  • Cold-morning voltage uses 0.30% per °C, typical for crystalline panels. This panel's own value is not published.
  • Expected watts are the best case in full sun. Real-world midday output is usually 60 to 80% of that.
  • Some numbers for Anker SOLIX PS400 Bifacial come from a shop listing we have not confirmed in the manual yet.
Sources
From the brand's pageF2600 spec page, solar input
Shop listing, not yet confirmedPS400 Bifacial label values
Checked Oct 28, 2026